ALWAYS  ENSURE  THAT  THE  MAIN         

EXTERNAL  ELECTRICITY  SUPPLY  IS 

SWITCHED  OFF  BEFORE  COMMENCING  ANY 

MAINTENANCE ON THIS HEATER. 

 

To  obtain  the  best  results  from  the  heater,  it  is 

essential  to  avoid  the  accumulation  of  dust  and 

dirt  within  the  unit  on  the  air  inlet  and  discharge 

grilles.  For  this  reason  regular  cleaning  is        

necessary. 

 

Cleaning of the fan is best carried out  with a soft 

brush. 

 

The product should be serviced annually.          

 

Servicing  shall  be  undertaken  by  a  competent  

person.  

 

6.2  General 

 

If the heater does not operate a competent service 

engineer should be called to identify the nature of 

the fault. 

 

 

All heaters are fitted with motor thermal protection. 

 

Other  faults  in  relation  to  the  element, motor  and 

wiring should be identified using conventional fault 

finding techniques. 

 

In  the  event  that  electrical  components  are       

replaced,  please  ensure  that  electrical  safety 

checks in accordance with the regulations in force 

in the country of use are undertaken. 

 

 

6.3 Thermal cut-out 

 

The  units  are  protected  from  overheating  in  the 

event  of  fan  failure  or  an  obstruction  of  the  free 

airflow,  by  thermal  cut  outs.    If  this  happens  the 

thermal cut outs switch off the appliance. The ap-

pliance  will  not operate until the heater is discon-

nected  from  the  mains  supply  and  it  has  cooled 

down. 

 

If  this  fault  re-occurs  again,  refer  to  the  section 

‘6.4 

fault finding

’. 

 

6. Servicing & Maintenance. 

6.1 Maintenance

 

6.4  Fault Finding 

 

If  the  heater  will  not  operate,  disconnect  it  from 

the mains and arrange for a certified electrician to 

attend and investigate the reason. 

 

 

6.5  Replacing the Fan Heater 

 

 

a) Split and remove shroud 

b) Remove the grille. 

c) Disconnect the internal wiring from the blower 

d) Remove the four screws fixing the fan heater 

assembly to the back of the case. 

e) The fan heater assembly can now be eased 

forward and removed from the heater case. 

f) Fit replacement fan heater and reassemble in 

reverse order. 

 

 

6.6  Spares 

 

It  is  essential  when  ordering  spares  or  replace-

ment  parts  to  state  the  model  number  and  the 

serial number on the rating label fixed to the side 

of the unit below the terminal cover. 

 

In  the  interest  of  progress  the  Company  reserve 

the  right  to  vary  specifications  from  time  to  time 

without notice.  The material listed is offered sub-

ject to the Company

s General Conditions of Sale, 

a copy of which can be obtained on request. 

Summary of Contents for HE7237SL

Page 1: ...ls 3 Electrical Connections 4 Operation 5 Servicing Maintenance 6 41001476 Iss 01 Surface Warm Ceiling Heaters Catalogue Numbers HE7237SL HE7247SL HE7267SL HE7237RX HE7247RX HE7267RX Installation and Operating Manual CONSORT Wireless controller CRX2 SLPB SLTI SLVT SLVTB ...

Page 2: ...be wired in accordance with I E E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller SL models The HE7237SL HE7247SL HE7267SL heaters are supplied without a controller The SL models will not work without the controller See section 5 1 for more details 1 5 Controller RX models The HE7...

Page 3: ...ocedures are adhered to during installa tion Sole liability rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product 1 General Information Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 ...

Page 4: ...d below It is required that two 10 mm hanging rods stud bars support each appliance beam The rods pass through and into each appliance beam Support washers together with nuts locate and lock the appliance beams after adjustment to level the appliance Replace Shroud Halves The reverse of above Slide shrouds beneath and around base panel Se cure each shroud half to each appliance beam with machine s...

Page 5: ... models Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail 41001476 Iss 01 SLPB SLVTB SLTI CONSORT Wireless controller CRX2 CONSORT SL Controllers 5 2 RX Models The heaters HE7237RX HE7247RX and HE7267RX can be controlled by CONSORT wireless con troller CRX2 The heaters will not work without a controller Each controller has unique identification code it can control unlimited number ...

Page 6: ...struction of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 Servicing Maintenance 6 1 Maintenance 6 4 Fault Finding If the heater will not operate disconnect it from ...

Page 7: ...7 ...

Page 8: ...r please contact our Helpline Consort Equipment Products Limited Thornton Industrial Estate Milford Haven Pembrokeshire SA73 2RT Tel 01646 692172 Fax 01646 695195 Email technical consortepl com Web www consortepl com Operation hours Mon to Thu 8 30am to 4 30pm Fri 8 30am to 3 30pm BS EN ISO 9001 Registered Company No FM12671 ...

Reviews: