Model Number: HE7230W

 

 

RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE

 

The Claudgen recessed ceiling heater is designed to fit in place of a 
standard  600mm  ceiling  panel.    It  is  supplied  complete  with  a 
remote mounting control

 box. 

 

IT  IS  ESSENTIAL  THAT  THE  CEILING  FRAME  IS  ADEQUATELY 
SUPPORTED TO SUPPORT THE WEIGHT OF THE HEATER, OR THAT 
THE  HEATER  IS  INDIVIDUALLY  SUPPORTED.    THERE  IS  PROVISION 
ON THE HEATER FOR CHAIN OR WIRE, SUPPORT OR MOUNTING.  
IT  IS  ALSO  ESSENTIAL  THAT  THE  HEATER  IS  NOT  INSTALLED  IN  A 
CONFINED  SPACE,  NEAR  VERTICAL  WALLS  OR  NEAR  THE  CORNER 
OF A ROOM. 

 

NB: Weight of HE7230W: 12.4 Kg 

 

I

NSTALLATION

 

Carefully unpack the unit and control box.  The unit is supplied with 
a  length  of  self-adhesive  foam  strip.    This  can  be  cut  into  lengths 
and is to be laid on the 4 sides of the ceiling frame (see Fig 3).  This 
will  ensure  that  the  unit  assembly  is  free  from  vibration.    The 
discharge  grille  and  diffuser  assembly  can  now  be  fitted  into  the 
ceiling frame (see fig 3). 

 

C

ONNECTION TO THE 

M

AIN 

S

UPPLY

 

This unit is suitable for connection to 230/240V 50Hz supplies. 
 
The HE7230W has a heating load of 3 kW. 
 
The  unit  must  be  wired  in  accordance  with  IEE  regulations  for  the 
Electrical  Equipment  of  Buildings  and  the  installer  should  ensure 
that a suitable isolating switch is connected in the mains supply. 
 
Fig. 2 shows wiring diagram. 
 
The  electrical  connections  are  accessible  so  that  the  unit  can  be 
wired in site (see Fig 1).

 

 

O

PERATION

 

This heater can only be used when connected to a CZC1 wireless 
programmable  timer

.    Each  CZC1  can  control  any  number  of 

heaters.    The  heater  has  an  indicator  light  positioned  behind  the 
fascia panel on the top right side.  The light may be: 
 

Green

 

-

 

when no heat is needed 

Yellow

 

-

 

when  some heat is needed to maintain the 

 

 

room temperature 

Red

 

-

 

when the heater is on full power 

Fast Flashing Red   -  

when the heater has overheated and the 

 

Electronic Safety Control has switched the 

 

heater off. 

 
Please refer to the CZC1 user and operating instructions for full 
operational details. 

 

M

OUNTING

 

The fan heater box can only be fitted one way round (see Fig.1), as 
2 of the studs are offset.  This ensures that the fan outlet lines up 
with  the  discharge  grille  and  also  that  the  wiring  is  always sighted 
the same side. 
 
The  diffuser  is  attached  to  the  discharge  grille  with  4  small  clips 
which can be removed if necessary. 
 
The  discharge  grille  has  4  additional  studs,  plus  nuts/washer,  to 
enable the unit to be chain mounted, if required. 
 
There  are  also  extra  holes  in  the  box  to  enable  the  unit  to  be 
suspended via wires. 
 

MAINTENANCE 

ALWAYS  ENSURE  THAT  THE  MAIN  EXTERNAL  ELECTRICITY  SUPPLY  IS 
SWITCHED OFF BEFORE SERVICING THIS HEATER. 
 
To  obtain  the  best  results  from  the  heater,  it  is  essential  to  avoid 
the  accumulation  of  dust  and  dirt  within  the  unit  on  the  air  inlet 
and discharge grilles.  Regular cleaning is necessary with particular 
attention  to  the  removal  of  any  dirt  on  the  fan  rotor  blades.  
Cleaning of the fan is best carried out with a soft brush.

 

 

E

LECTRONIC 

S

AFETY 

C

ONTROL

 

 

The  appliance  is  fitted  with  an  Electronic  Safety  Control  (ES).  

This  is  a  safety  device  which  switches  the  heater  off  if,  for  any 
reason, the appliance overheats.  The overheating is indicated by a 
fast flashing red light.  The ES control can only be re-set after the 
appliance  has  cooled  down.    In  order  to  re-set  the  ES  control, 
proceed as follows: 
 

 

Switch the appliance off at the mains by using isolator switch 
and leave to cool down for approximately 5 minutes. 

 

Switch appliance back on and the ES control will re-set. 

 

Ensure  that  the  appliance  is  functioning  correctly.    If  the  ES 
control operates again, the appliance should be checked by a 
competent electrician. 

 

TO REPLACE A FAN/HEATER ASSEMBLY 

a)

 

Switch off the mains supply 

b)

 

Release the six nuts and washers fixing the fan heater box to the 
discharge grille 

c)

 

Disconnect the wiring  

d)

 

Remove the fan heater from the box (four screws) 

e)

 

Fit the replacement unit and re-assemble in the reverse order.

 

 