background image

 

 

 

51000486 Iss 01

 

 
All electrical appliances produced by the Company are guaranteed for one year against faulty 
materials  or  workmanship.    This  applies  only  if  the  appliance  has  been  used  for  purposes  in 
accordance  with  the  instructions  provided  and  has  not  been  connected  to  an  unsuitable 
electricity supply, or subject to misuse, neglect, damage or  modified or repaired by any person 
not authorised by us. This guarantee is offered to you as an extra benefit and does not affect your 
legal rights. 

 

The correct electricity supply voltage is shown on the rating label attached to the appliance. 
 
Reasonable care has been taken to ensure that this guide is accurate at the time of printing.  
In the interest of progress the Company reserve the right to vary specifications from time to time 
without notice.

 

Commercial Fan Heater

 

Installation and Operating Manual

 

 

 

Catalogue Numbers: CH06CSiRX, 

CH06CPiRX, CH09iRX, CH12iRX.

 

 

 

       Installation and Operating

 

                        Manual

 

Summary of Contents for CH06CPiRX

Page 1: ...any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached...

Page 2: ...he CRXSL wireless controller 4 5 CHMC controller 4 6 Connecting heaters to the CHMC controller 5 Dimensions and fixing location 6 Installation details 6 1 Mounting 6 2 Electrical connections 7 Technic...

Page 3: ...ng points are suitable for the weight of the appliance 1 3 Electrical Supply This heater must be permanently con nected to the electricity supply via a double or 4 pole switch having 3mm gap on each p...

Page 4: ...ons re mote temperature measuring microwave occupancy sensor and remote or boost switch connection All functions are fully pro grammable and can be associated with any heaters in the system The contro...

Page 5: ...d depend ing on which heat mode is activated it will calculate the best possible airflow and adjusts the fan speed accordingly In order to maintain a constant airflow temperature the fan runs at a low...

Page 6: ...eater controls 4 3 Heater status indication 4 4 Operation of CRXSL The CRXSL controller will come factory set in temperature control mode This can be changed to manual operation mode which simulates a...

Page 7: ...the heater by CAT5 CAT6 RJ45 cable The RJ45 connector is located under the terminals cover on the bottom of the heater There are 2 equal RJ45 connectors in each heater The con troller can be connecte...

Page 8: ...the heater to the wall bracket Finally adjust the direction of the heater to the desired area and tighten up all clamp ing nuts and bolts Care should be taken when choosing a posi tion ideally there s...

Page 9: ...urrent per phase A pha 8 5 13 16 5 Max motor power W 120 120 120 External fuse size amps A pha 16 16 20 Controller CRXSL wireless or CHMC Touch screen controller Controller wiring CAT5 CAT6 with RJ45...

Page 10: ...load kW 26 Max current A pha Max motor power W 120 External fuse size amps A pha 32 Controller CRXSL wireless or CHMC Touch screen controller Controller wiring CAT5 CAT6 with RJ45 connectors Cable ter...

Page 11: ...11 51000486 Iss 01 8 Wiring Details 8 1 Installer Wiring 3 phase heaters CAT5 cable...

Page 12: ...12 51000486 Iss 01 8 Wiring Details 8 2 Installer Wiring single phase heaters CAT5 cable...

Page 13: ...13 51000486 Iss 01 8 3 Factory Wiring 3 phase heaters temperature sensor...

Page 14: ...14 51000486 Iss 01 8 4 Factory Wiring single phase heaters temperature sensor...

Page 15: ...LEDs on the RJ45 connect ors indicating that the power is available If the heater is in stand by mode the green LED is ON If the heater is switched ON the orange LED is indicating that the auxil iary...

Page 16: ...onfigura tion All possible addresses RS485 serial half duplex interface MODBUS RTU 9600 baud 8 bits 1 start bit no parity 2 stop bits mark parity 1 stop bit Supported MODBUS function codes 0x03 read m...

Page 17: ...gn for Energy Related Products and Energy Information Amendment EU Exit Regulations 2019 SI 2010 2617 The Restriction of use of Certain Hazardous Substances SI 2012 No 3032 Transposed standards used B...

Page 18: ...18 51000486 Iss 01...

Reviews: