Figure 9
E-9
CONTROL
SECTION 5: 208/240V WIRING INSTRUCTIONS
1.) Loosen the screw securing the junction box cover and remove the cover.
2.) Pull the power supply wires through the hole in the cover.
3.) Pull out the 5 wires marked L1, L2, N, G, S from the junction box on the side of the
builder box.
4.) Connect the black L1 wire and red L2 from the unit to the two dedicated 15 amp
lines from the power supply.
5.) Connect the white N wire from the unit to the white N from power supply.
6.) Connect the green ground G wire from the unit to the ground from the power supply.
7.) Plug the S wire connector into the provided sign wire.
8.) Ensure that all connections are tight.
9.) Secure all the wiring with wire-caps, then insert into the junction box.
10.) Remount the junction box cover (see figure 8 & 9.)
Note: 36EB220-GRT & 36EB221-GRC will only run on 208/240 volt operation.
208/240 V
Configration
Summary of Contents for 36EB110-GRT
Page 12: ...SECTION 10 WIRING SCHEMATIC E 12 36EB110 GRT ...
Page 13: ...36EB220 GRT E 13 ...
Page 14: ...E 14 36EB111 GRC ...
Page 15: ...36EB221 GRC E 15 ...