18
947226
Master Clock Schedule
The Master Clock Schedule has 6 separate schedules with up to 256 total events. The user
defines how these events are to be distributed between schedules.
Dial codes may be used to force a schedule or to turn a schedule off. #94X forces schedule on
with the X being the number of the schedule (i.e. #941 will force Schedule 1). #940 turns off the
active schedule.
•
Select Schedule 1-6.
•
Click Open.
•
Displays Schedule 1 menu.
•
Choose which days schedule is to be active.
•
Select Add.
New Event Screen menu will be shown. Select Start Time. Select which Relay Type you want
to follow the Schedule, and Select the Relay Duration of the contact closure. Select which Page
Group(s) tone should go to. Select Save.
NOTE:
The contact closure pairs 13, 14, 15, 16 on the system punchdown block, should be
wired to the tone select input of an external tone generator (V-9927A). The tone output of the
external tone generator should then be wired to the external tone input of the VC-24, pair 5 of the
system punchdown block.