PUTTING INTO OPERATION
CONNECTION TO THE COMPRESSED AIR SYSTEM
- Compressed air enters into the jack circuit through the quick
coupling on the top of the manual lifting/descending controls; it is
therefore necessary to have a connecting pipe with a quick coupling
compatible with that of the jack.
Check that the air supply pipe has a useful passage of at least 6 mm
and it is not pinched or restricted anywhere. DWG. 7
Working air pressure: 8 - 10 bar
- Absolutely never put the following into the compressed air circuit: hydraulic or Vaseline oil, brake liquid, kerosene
or other liquids.
- Install a fi lter dehumidifi er-lubricator unit in the compressed air system.
- If you want to lubricate the compressed air circuit use exclusively:
AGIP OSO 100; MOBIL DTE 27; ESSO TERESSO 100; SHELL TELLUS 100; BP ENERGOL HP 100
ACCESSORIES
The jack can be supplied with two extensions or height adaptors (long extension 100mm, short extension 50mm.)
Never use more than two extensions! The manufacturer is not liable for any damage
resulting as a consequence of disregard for the above indications and the warranty
conditions are invalidated thereof!
SCRAPPING AND DISPOSAL
- The lubricants must be disposed of in compliance with the anti-pollution laws in force.
- Scrapping the jack and its component parts must be carried out by the user in accordance with current laws.
OP 0307
PNEUMATIC FLOOR JACK 2T-3 STAGES