HU 0607
AD BLUE FUNNEL 1,1l (VERTICAL)
MODIFY THE CORRECTION FACTOR ON SITE
Wait for the meter to go standby.
Reset the total volume that can be reset.
Start dispensing the liquid into a measuring
cup.
Stop the operation after dispensing a
volume greater than 5 litres, and read the
current value.
The volume displayed on the LCD screen
is the «Displayed Value», not the «Current
Value» which may be slightly higher.
For example, in the fi gure on the right,
the «Displayed Value» is 18.96 while the
«Current Value» is equal to 20.75. Press
the «Move» button. Keep it pressed until
the screen displays an image identical to
the one on the right (the number fl ashes in
zone 1). Press the «Move» button to access
the next digit in order to enter the «Current
Value».
Check that the correction factor is correct,
and then press the «Move» button. Press
and hold this key until the calibration is
complete and the factor is saved. The
counter will then return to standby.