HU 0607
AD BLUE FUNNEL 1,1l (VERTICAL)
USER BUTTONS
1. 5 digital liquid crystal display for both volume each
time and total
2. 4 units: L, GAL, PT and QT
3. Accurate to the second decimal place
4. Low battery indicator
5. two buttons: “Move”, “Reset”
LCD DISPLAY KEY
1. Partial register (5 figures with moving comma from 0.1
to 99999). Indicating the volume dispensed since the
reset button was last pressed.
2. Indication of battery charge
3. Indication of calibration mode
4. Indication of resetting present total to Zero
5. Total register
6. Indication of flow rate mode
7.
Indication of unit of measurement of partial:
L= Litres; GAL = Gallons; PT = Pint; QT = Quarts
KEY USAGE
The oval gears digital meter features two buttons
(«Move» and «Reset») which individually perform two
main functions and together, other secondary functions.
The main functions performed are:
• For the «Reset» key, resetting the partial register and
reset table total (reset total)
• For the «Move» key, entering instrument calibration
mode.
•
Used together, the two keys permit entering
configuration mode,
RESET THE TOTAL PRESENT VOLUME
1. When the meter is on standby, press the RESET key.
2. The display shows all the segments.
3. The meter resets the present total already.
OPERATING INSTRUCTIONS