48.5kW DIESEL FIRED SPACE HEATER WITH
EXCHANGER
Problems
Solutions
The generator does not start.
Check :
• Correct electrical connections.
• If the environmental thermostat is fi tted, make sure
that it is not set too low.
The fan does not start.
Check :
• Motor power supply cable.
The fan starts but there is no bustion (the "Reset" push-
button LED comes on after a few seconds).
• Check the fuel level.
• Make sure that the fuel oil filters are not
comclogged.
• Make sure that the nozzle is not obstructed.
• Make sure that no air enters the fuel circuit.
• Dirty photo sensitive cell. Remove from support and
clean.
• Flame control system faulty: replace.
• Make sure there is a spark between the electrodes.
If this is not the case, check the position of the
electrodes, their integrity and the status of the high
voltage cables.
• Check the fuse on the pc board.
• Make sure that he transformer is not burnt out.
The unit overheats during normal operation.
• Excess flow of fuel caused by nozzle wear or
installation of a nozzle having different features than
the original.
• Obstructions in the ventilation air route.
When the unit is switched off using the main switch or
the environment thermostat, the fan does not operate
and the generator overheats.
• Pc board broken. Replace
The unit discharges lightcoloured fumes.
• Excess air or poor fuel.
• Impurities in the fuel circuit: clean the tank, the filer
and the ducts. Change the fuel.
• Switching on or off the appliance, you could see
lightcoloured
fumes caused by the natural evaporation of the
ceramic
material in the combustion chamber.
The unit discharges dark fumes.
• Air defect or excess fuel, caused by clogged or
nonconforming nozzle: replace.
• Modifi ed fuel pressure fl ame turbo obstructed: clean.
TROUBLE SHOOTING