Care and cleaning
If needed, wipe the inverter with a damp cloth. Check regularly and tighten
the screws on the DC input if needed.
Disposal
Follow local ordinances when disposing of this product. If you are unsure
about how to dispose of this product contact your municipality.
Troubleshooting
Problem
Possible cause
Possible solution
Low output voltage
110 V: 95–105 V AC
220 V: 190–210 V AC
The measuring
instrument can not
read “True RMS”.
Use a measuring
instrument that can
read “True RMS”.
No output voltage.
Low input voltage.
Recharge the battery.
No output voltage.
The switch is in
position
0
.
Set the switch to
position
1
.
No output voltage and
no voltage indication.
Blown fuse.
Change fuse.
No input voltage and
the voltage indicator is
not visible.
High input voltage.
Check that the input
voltage is 12 V.
Low input voltage.
Defective DC
connection.
Use suitable cables and
make a proper connec-
tion.
Warning signal.
Overheating.
Let the inverter cool down
before turning it on again.
Warning signal.
Overload.
Turn off the inverter,
decrease the load and
then turn it on again.
Low output voltage.
Defective connections,
short-circuits or over-
load .
Check the AC connections,
make correct connections
or decrease the load.