6
English
C
F
B
C
C
F
A
A
A
E
I
I
I
E
E
Lid handle, thermometer and air-vents
1. Mount the handle (1) onto the lid (3).
Place the handle reinforcement plates
(5) on the inside of the lid and use
four M6 x 10 screws (B) for screwing
the handle securely into place.
2. Mount the air vents (4) onto the lid’s
sides by using two M6 × 15 screws
(C) and two M6 nuts (F) for securing
into place.
3. Mount the thermometer onto the lid
by ensuring that the pin sits into its
insertion hole. Tighten the nut with
moderate strength to secure.
Bottom section air vents and ash extraction door
1. Mount one air vent onto the side of the bottom section (9), and the other vent onto
the ash extraction door (7). Use two M6 × 15 screws (C) and two M6 nuts (F) for
securing into place.
2. Mount the ash extraction latch (6) onto the ash extraction door. Use one M4 × 10
screw (A), one flat washer M4 (I) and one M4 nut (E).
3. Mount the catch onto the bottom section. Use two M4 × 10 screws (A), two flat
washers M4 (I) and two M4 nuts (E) for securing into place.
4. Mount the ash extraction door onto the bottom section. Use two M4 × 10 screws
(A), two flat washers M4 (I) and two M4 nuts (E) for securing into place.
Summary of Contents for 31-1161
Page 2: ...2 ...
Page 5: ...5 E ngl i sh 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 Exploded view ...
Page 12: ...12 S ve n sk a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 Översikt ...
Page 19: ...19 N orsk 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 Oversikt ...
Page 26: ...26 S uomi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 Yleiskuva ...
Page 33: ...33 Deut s ch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 Übersicht ...
Page 38: ...38 ...
Page 39: ...39 ...