![Clarke YDE20 Operation & Maintenance Manual Download Page 13](http://html.mh-extra.com/html/clarke/yde20/yde20_operation-and-maintenance-manual_2614615013.webp)
13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
TECHNICAL SPECIFICATION
Cause
Solution
No operation
Power cable
disconnected.
Insert the plug into a power
socket.
Water tank is full.
Empty the water tank.
Water tank is not seated
properly.
Replace the tank correctly in
position.
Dehumidified
volume is small
Filter is dirty.
Clean the filter as described
See page 12.
Check to see if the air inlet
is blocked.
Remove dirt from the air inlet.
Operation
stops during
spot
dehumidifying
The room temperature is
higher than the usable
operating temperature.
Dehumidifying operation will
restart automatically when the
temperature falls.
Washed
clothes are not
dried
Washed clothes are hard to
dry when the temperature
is low.
Check to see if the room
temperature is too low.
Power Source
230V AC 50Hz
Input Power
370W
Water Tank Capacity
5 Litres
Weight
14 kg
Operation Temperature
5 - 32 degrees Celsius
Dimensions (L x W x H)
239 mm x 388 mm x 598 mm
Refrigerant
R1
34
G (Qty. 1
70
g)
Extraction Rate (Max)
20 litres per day (@ 30°C 80% RH)
Max Allowable Pressure
Low Pressure Side - 0.5 mpa, High Pressure Side - 1.5 mpa
Summary of Contents for YDE20