background image

FAULT FINDING

Air Valve Plate (item
33) or Air Valve (item
38) damaged.

Diaphragm (item 31)
damaged

Cyl Head screws loose
(item 42)

Air hose leaking

Cyl Head Screws too
tight.

Bearing Fault

Cyl Head Screws too
tight.

Armature faulty

Armature faulty

Thermal cut-out has
operated

Renew defective Air Valve
Plate or Air Valve.

Renew Diaphragm

Tighten screws to 10 lbf ft

Check seal or renew Air
Hose

Back off all screws and
tighten equally.. .to 10 lbf ft

Consult your Clarke dealer

Back off all screws and
tighten equally.. .to 10 lbf ft

Consult your Clarke dealer

Consult your Clarke dealer

Switch OFF and
disconnect. Wait for 15-20
mins and try again.

Low air flow

Noisy operation

Compressor
hums but does
not work.

Compressor
does not work.

PROBLEM

PROBABLE CAUSE

REMEDY

SPECIFICATIONS

Motor ............................................................... 230V 50Hz 1 Ph

Power Rating .................................................. 1/8HP

Rotational Speed ........................................... 1500RPM

Max Pressure ................................................... 40psi

Air Displacement ............................................ 1.58 cuft/min

Fuse Rating ...................................................... 13amps

Cyl. Head Bolt torque setting ....................... 10 lbf ft

Weight ............................................................. 4.3kg

7