Thank you for purchasing this CLARKE Water Pump, which is  particularly suitable
for the filtration of small to medium size swimming pools and ponds and for pumping
clean water or water containing small solids in suspension.

To help ensure long, trouble free performance and the protection afforded by
the warranty, please carefully  follow all the instructions and recommendations
given in this booklet.

GUARANTEE

This CLARKE product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered
with in any way, or not used for the purpose for which it was intended.

Faulty goods should be returned to their place of purchase. No product can be
returned to us without prior permission. This guarantee does not effect your
statutory rights.

SAFETY PRECAUTIONS

1.

Ensure the pump is installed in a horizontal position with the outlet facing
vertically upwards, and that it is firmly anchored via its fixing screws.

2.

Ensure there is an adequate air flow around the pump. DO NOT mount it in an
enclosed atmosphere.

3.

Ensure all water pipes - supply or discharge, are adequately  supported where
necessary, so as not to put a strain on the pump connections.

4.

DO NOT allow the pump to run dry, as this will cause serious damage to the
pump  seals.

5.

Ensure the inlet to the pump is completely unrestricted.

6.

Ensure the pump is protected from the elements, neither the motor nor the
electrical terminal box is intended to be waterproof.

7.

Ensure that all pipes are protected against damage where necessary, and
that they are suitably lagged to avoid the possibility of freezing during cold
weather.

8.

NEVER switch the pump ON when the pool is in use. ALWAYS disconnect the
pump from the electrical supply.

9

.

THIS PUMP MUST BE CONNECTED TO THE ELECTRICAL SUPPLY VIA A
RESIDUAL CURRENT DEVICE (RCD)

2

Summary of Contents for SPP3

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS POND PUMP Model Nos SPP3 SPP6 0200 ...

Page 2: ... effect your statutory rights SAFETY PRECAUTIONS 1 Ensure the pump is installed in a horizontal position with the outlet facing vertically upwards and that it is firmly anchored via its fixing screws 2 Ensure there is an adequate air flow around the pump DO NOT mount it in an enclosed atmosphere 3 Ensure all water pipes supply or discharge are adequately supported where necessary so as not to put ...

Page 3: ...l marked with N or coloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewirable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 Should you wish to replace a detachable fuse c...

Page 4: ...sition i e with the outlet port see Fig 1 facing vertically upwards The fixing slots in the base should be used as necessary to secure the pump firmly in its operating position Also ensure that there is adequate air circulation around the motor Avoid situations where there is the risk of water coming into contact with the outside of the pump Neither the motor or the terminal box are intended to be...

Page 5: ... Clarke International Service Department for advice B GRAVITY FEED Do not place any restriction on the inlet side of the pump The delivery head i e the vertical distance between the pump outlet and the point of discharge should not exceed distance specified for your pump see Specifications page 7 To prevent unnecessary strain or possible distortion to the pump ensure that adequate support is provi...

Page 6: ... 2 Check to see that no foreign matter is fouling the intake system check the strainer is not blocked or obstructed Should you still experience problems then contact your Clarke dealer or CLARKE International Service Department for advice Please contact your nearest dealer or CLARKE International on one of the following numbers PARTS SERVICE TEL 020 8988 7400 PARTS SERVICE FAX 020 8558 3622 or e m...

Page 7: ... Max Output 60 L min 3 6M3 h 100 L min 6M3 h Insulation Rating IP44 IP44 Dimensions LxWxH 255x150x190mm 255x150x190mm Part No 7175010 7175020 NOTE As the pumping head is increased so the flow rate of water will decrease Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications a...

Page 8: ...PARTS DIAGRAM 8 ...

Page 9: ...P1240012 6 Sealing ring LDP1200027 7 Gasket LDS3500199 8 Terminal box LDS3500214 9 Capacitor LDP1360009 10 Screw LDP1100004 11 Seal LDP1200021 12 Screw LDP1100006 13 Cover LDP3500218 14 Screw LDP1100006 15 Washer LDP1120003 16 Cable clamp LDP1510004 17 Switch assembly LDP1380001 18 Power Cable LDP1330013 19 Nut LDP1510009 20 Cable Gland LDP1230001 21 Motor Assembly n a 9 ...