5
The delivery head i.e. the vertical
distance between the pump and
the point of discharge should not
exceed distance specified for your
pump (see Specifications, page
7).
When suction lift is used to draw
water into the pump it is essential
that all connections and hoses are
1.
With the pump, all inlet pipes/hoses and the foot valve in position, slowly pour
water into the outlet port. Wait until all air is expelled...this may take a minute
or two...and fill to the brim before connecting the outlet hose to the outlet
port. The hose is then led away to the water filter.
2.
Switch on the pump. Water should start to flow through the system.
Check for leaks and repair as necessary
Do not allow the pump to run dry, otherwise the seal between the pump and motor
may be damaged. If a leak is noticed at this point it may indicate that the seal is
worn and therefore in need of replacement. Contact your CLARKE dealer, or the
Clarke International Service Department for advice.
B
GRAVITY FEED
Do not place any restriction on the
inlet side of the pump.
The delivery head i.e. the vertical
distance between the pump outlet
and the point of discharge should
not exceed distance specified for
your pump (see Specifications, page 7).
To prevent unnecessary strain or possible distortion to the pump, ensure that
adequate support is provided to the hoses and/or pipes. Remember they will be
considerably heavier when filled with water.
Remember - this pump is designed for pumping CLEAN WATER with small solids in
suspension, ONLY. DO NOT USE for pumping chemicals or other corrosive liquids
(other than pool purification chemicals in their correct mix ratio).
Protect the pump and pipework from
freezing.
The formation of ice may cause
serious damage.
NOTE: For the fitting of filters/strainers, please consult the manufacturers manual.
completely air tight, otherwise the system will
not work.
Before pumping will start it is essential to
completely fill the suction side with water. This
is known as
priming the pump
and is carried
out as follows :-
Fig.4
Fig.3