background image

5

Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]

INSTALLATION

Because of the variety of possible installations, no plumbing accessories are
supplied with your pump, however accessories are available from your
nearest CLARKE dealer. Contact your CLARKE dealer for further information,
or CLARKE International Sales Department on 01992 565333.

Note: It is recommended that the end user should consult a qualified installer

if there are any doubts as to the suitability of this product for a particular
installation.

IMPORTANT: The pump MUST NOT be connected to the mains power supply
until all hose/pipe installation is completed.

INSTALLATION OF THE PUMP

A typical installation of the pump is shown in Fig 1. The pump must always be
installed and operated in a horizontal position i.e. with the outlet port facing
vertically upwards. The fixing holes in the base should be used to secure the
pump firmly in it’s operating position. Mount the pump on raised blocks or a
purpose built platform to protect it from flooding.

Always ensure there is adequate air circulation around the motor and that
the transparent filter cover is accessible so that the filter basket can be
removed for cleaning. The pump should be installed in a dry, well ventilated
enclosure, sheltered from rain, such as a purpose built pump room.

The pump is usually installed between the pool skimmer and the pool filter
and should be positioned as near to the pool water level as possible.

Fig 1

Pool

Skimmer
outlet

Pool Filter

Pool Side

Remote Power
Connection

Summary of Contents for SPP10 7175030

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC12 11 1HP SWIMMING POOL PUMP Model SPP10 Part No 7175030 ...

Page 2: ...ion and the use of a non return valve will facilitate immediate priming The pump inlet is higher than the impeller inlet so that it can start operating when only the pump body is filled with water Upon receipt any damage or deficiency should be reported to your CLARKE dealer immediately CONTENTS 1 x Swimming Pool Pump c w integral Pre filter Basket 2 x Inlet Outlet Connectors 2 x Inlet Outlet Conn...

Page 3: ...ear 6 ALWAYS maintain the pump with care and keep it clean for best safest performance 7 NEVER use this product if any part is damaged Have it inspected and repaired by your local Clarke dealer Always turn the pump off before carrying out any maintenance 8 NEVER modify this pump in any way Use it ONLY for the purpose for which it is designed 9 NEVER use for pumping flammable liquids or corrosive c...

Page 4: ...iring instructions shown below The old plug must be disposed of safely as insertion into a mains socket could cause an electrical hazard WARNING The wires in the power cable of this product are coloured in accordance with the following code Blue Neutral Brown Live Yellow Green Earth If the colours of the wires in the power cable of this product do not correspond with the terminal markings of your ...

Page 5: ...TION OF THE PUMP A typical installation of the pump is shown in Fig 1 The pump must always be installed and operated in a horizontal position i e with the outlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Always ensure there is...

Page 6: ...the use of suitable 50 mm I D hose secured with a worm drive clip Ensure all connections are air tight Tighten them enough to secure the hose during pressurised operation but not so tight as to crack the plastic inlet outlet connectors Where the pump is to be a permanent fixture vibration and strain on adjacent parts can be reduced by the insertion of a short flexible section of hose between any r...

Page 7: ...ming process and it is suggested that a non return valve be fitted to the end of the suction pipe 5 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor may be damaged If a leak is noticed at this point it may indicate that the seal is worn and therefore in need of replacement Contact your CLARKE dealer or ...

Page 8: ...has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both inside and out It should then be drained before replacing the drain plug and covered over if not already installed in a clean dry environment sheltered from the weather Remember to re prime the pump when returning to service In the event that dismantling and overhaul of the pump is ne...

Page 9: ...k s a b r e t l i f n a e l c d n a k c e h C e d i s n i l a i r e t a m d e t s e g n o C p m u p t e k s a b r e t l i f t u o n a e l C p m u p h s u l f k c a b e n i l y r e v i l e d r o n o i t c u S d e t c u r t s b o e r u s n e d n a n o i t c u r t s b o e v o m e R e n i l y r e v i l e d n i s k n i k o n e r a e r e h t e g a k a e l e p i p t e l n I r o t c e n n o c d n a e p i ...

Page 10: ...p i p t e l n i n i e c n a t s i s e R y b d e s u a c n o i t c u r t s b o s a t u o n a e l c d n a e p i p k c e h C y r a s s e c e n t n e n o p m o c g n i t a t o r e s o o L r o f r e l a e d r u o y o t n r u t e R s r i a p e r s i p m u p f o n o i t a l l a t s n I e l b a t s n u n o i t i s o p e r d n a p m u p p o t S r o p m u p n i t e k c o p r i A e n i l e p i p r e l l e p ...

Page 11: ... e p y T e v l a V n r u t e R t e l t u o t a e p y t p a l F e z i S t e l t u O t e l n I m m d o 6 5 d i 0 5 y l p p u S r e w o P z H 0 5 V 0 4 2 0 2 2 r e w o P t u p t u O W 0 5 7 P H 1 l e v e L e r u s s e r P d n u o S A p L B d 8 8 6 l e v e L r e w o P d n u o S A w L B d 3 5 7 r e w o P d n u o S d e e t n a r a u G A w L B d 8 7 e p y t p m u P l a g u f i r t n e C Please note that ...

Page 12: ... r e h s a W 4 1 0 1 P P S G Z 8 5 4 w e r c S e n i h c a M d H X 5 4 0 1 P P S G Z 6 5 1 r e h s a W e v a W 5 1 0 1 P P S G Z 2 1 6 4 x o B r o t i c a p a C 6 4 0 1 P P S G Z 1 6 1 t l o B x e H 6 1 0 1 P P S G Z 8 7 4 t e k s a G 7 4 0 1 P P S G Z 1 7 1 d n a l G f o o r p r e t a W 7 1 0 1 P P S G Z 1 8 4 r o t a t S r o t o M 8 4 0 1 P P S G Z 1 8 1 t r o p p u S p m u P 8 1 0 1 P P S G Z 1...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 16: ......