Squeegee System
86
Service Manual – MA50 15B
Troubleshooting
Problem
Cause
Correction
Poor Water Pick-Up
Vacuum leak(s) due to;
•
Leaky Vacuum hose
• Damaged pick-up adapter tube
• Recovery tank drain plug not
installed properly
• Recovery tank cover is mis-
aligned, or damaged
• Check the vacuum hose, and
tighten/replace as necessary
• Replace pick up adapter tube
•
Insure drain plug is installed
correctly
•
Check the cover, and adjust/
replace as necessary
Restrictions due to build up of
debris;
•
In the recovery tank or
standpipe
•
In the vacuum hose
•
In the squeegee assembly
Check the standpipe, check the
vacuum hose, and squeegee
assembly for accumulated dirt.
Clean as required
.
Squeegee blades are worn,
not installed correctly, or out of
adjustment
Check the squeegee blades
for proper installation, wear, or
damage. Replace as required.
Adjust the squeegee blades and/or
down pressure.
Summary of Contents for MA50 15B
Page 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...
Page 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...
Page 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...
Page 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...
Page 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...
Page 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...
Page 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...