![Clarke Little Devil II Operation & Maintenance Instructions Manual Download Page 9](http://html1.mh-extra.com/html/clarke/little-devil-ii/little-devil-ii_operation-and-maintenance-instructions-manual_2614856009.webp)
9
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
VENTILATION
STARTING PROCEDURE
!
TO START THE HEATER
1. Follow all installation, ventilation, and safety information.
2. Locate the heater on stable and level surface.
• Make sure strong drafts do not blow into the front or rear of the
heater.
3. Plug the heater into a suitable 230V mains socket.
• The motor will start, the fan will turn, forcing air from the front of the
heater.
4. Set the on/off switch to the on position.
5. Open the propane supply valve on the propane tank(s) slowly.
NOTE:
If not opened slowly, the excess-flow check valve on the propane tank
will stop the gas flow. If this happens, close the propane supply valve
and open again slowly.
WARNING: PROVIDE AT LEAST A 1.5 FT
2
(1400 CM
2
) OPENING OF FRESH,
OUTSIDE AIR WHILE RUNNING HEATER. IF PROPER FRESH, OUTSIDE AIR
VENTILATION IS NOT PROVIDED, CARBON MONOXIDE POISONING CAN
OCCUR. PROVIDE PROPER FRESH, OUTSIDE AIR VENTILATION BEFORE
RUNNING HEATER.
WARNING: BEFORE STARTING THE HEATER, YOU MUST ENSURE THAT THE
MINIMUM VENTILATION REQUIREMENTS ARE OBSERVED TO AVOID THE
RISK OF CARBON MONOXIDE POISONING.
WARNING: MAKE SURE THAT THE MOTOR AND FAN ARE RUNNING BEFORE
PUSHING IN AUTOMATIC CONTROL VALVE BUTTON. FLAMES COULD
FLASH OUTSIDE HEATER IF THE MOTOR AND FAN ARE NOT RUNNING.
Summary of Contents for Little Devil II
Page 16: ......