6. Push in and hold the automatic
control valve button.
7. Push the piezo ignitor button.
• You may need to push the
piezo ignitor button 3-8 times
until the burner lights.
• When the burner lights, keep
the automatic control valve
button pushed in.
8. Release the automatic control valve button after 30 seconds.
NOTE:
If the heater fails to ignite, the hose may have air in it. If so, keep the
automatic control valve button pressed and wait 20 seconds. Release
the automatic control valve button and wait 20 seconds for unburned
fuel to exit the heater, repeat steps 6-8.
NOTE:
If the heater is unplugged or a power outage occurs while the
heater is
running
,
the thermal
limit device will stop fuel flow.
A few se
c
onds
occur before the thermal l
i
mit device act
i
vates. During this short time
,
flames may appear outside the heater
.
Th
i
s is normal. The flames will
go
out when thermal limit device activates.
STOPPING PROCEDURE
TO STOP THE HEATER
1. Tightly close propane supply valve on propane tank(s).
• The heater will burn away gas left in supply hose.
2. Allow the heater to cool down for 5 minutes, then switch off the heater .
3. Unplug the heater.
TO RESTART THE HEATER
1. Wait five minutes after stopping the heater.
2. Repeat steps under 'To Start The Heater’.