Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0813 GAS HEATER Model No Little Devil II inc ss PART NO 6926020 6926025 SS...
Page 2: ...these cases the local regulations should be consulted by the user GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your r...
Page 3: ...t Dust is combustible 10 Keep the heater at least six feet from propane tank s Do not point the heater at propane tank s within 20 feet 11 Keep propane tank s below 100o F 37 8o C 12 Check the heater...
Page 4: ...influence of alcohol or those at high altitude are more likely to be effected by Carbon Monoxide CO can build up in a confined space and failure to provide adequate ventilation can be fatal The early...
Page 5: ...k The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly reco...
Page 6: ...provides a stream of clean hot air THE IGNITION SYSTEM The piezo ignitor lights the burner THE AUTOMATIC CONTROL SYSTEM Should the flame extinguish for any reason the thermocouple will quickly cool ca...
Page 7: ...VENT OF A GAS LEAK 1 Put out all smoking materials and other open flames 2 Do NOT operate electric switches or light matches 3 Close all supply valves on gas tank or cylinder 4 Do NOT use your phone U...
Page 8: ...nk You must use the regulator supplied with heater 4 Open the propane supply valve on the propane tank s slowly NOTE If the supply valve is not opened slowly the check valve on the propane tank will a...
Page 9: ...ank s slowly NOTE If not opened slowly the excess flow check valve on the propane tank will stop the gas flow If this happens close the propane supply valve and open again slowly WARNING PROVIDE AT LE...
Page 10: ...ontrol valve button and wait 20 seconds for unburned fuel to exit the heater repeat steps 6 8 NOTE If the heater is unplugged or a power outage occurs while the heater is running the thermal limit dev...
Page 11: ...nspect the heater before each use Check connections for leaks Apply mixture of liquid soap and water to connections Bubbles forming show a leak Correct all leaks at once 3 Inspect the hose regulator a...
Page 12: ...r dealer for repair Defective motor Return to your dealer for repair Heater will not ignite User did not follow installation or operation instructions properly Repeat installation and operation instru...
Page 13: ...hile running High surrounding air temperature causing thermal limit device to shut down heater This can happen when running heater in temperatures above 85o F Only run the heater in cooler temperature...
Page 14: ...GFLDEV204 17 Hose regulator Assembly GFLDEV217 5 Fan GFLDEV205 18 Regulator Connector GFLDEV218 6 Thermal Switch Kit GFLDEV206 19 Air Tube GFLDEV219 7 Burner Tube Part 2 GFLDEV207 20 Piezo Ignitor GF...