13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
CLEANING THE NOZZLE
If the nozzle becomes partially clogged with foreign material such as dirt or
limescale, excessive pressure may develop and the pump pressure will
pulsate. Clean the nozzle immediately as follows:
1. Turn off the power washer and turn off the water supply.
2. Pull the trigger to relieve any water pressure.
3. Disconnect the lance from the spray gun.
4. Remove any obstructions by directing water supply into the end of the
lance for 30 seconds to back flush loose particles.
5. Reconnect the lance to gun and turn on water supply.
REMOVING THE SPRAY GUN FROM THE HOSE
The gun can be disconnected from the hose for cleaning or to unblock the
spray gun/hose by disconnecting the connection using a 17 mm spanner.
Pull the hose away from the spray gun.
CLEANING THE WATER INLET FILTER
This filter should be checked periodically and cleaned if necessary.
1. Remove filter from the water inlet
of the pump as shown.
2. Clean the filter by flushing both
sides with water.
3. Replace the filter into the water
inlet.
• The tapered side faces inwards.
NOTE:
Do not operate power
washer without filter properly
installed.
WARNING: THE MACHINE SHALL BE DISCONNECTED FROM THE POWER
SUPPLY BY REMOVING THE PLUG DURING CLEANING OR MAINTENANCE
AND WHEN REPLACING PARTS.
Summary of Contents for JET 9000
Page 24: ......