Thank you for purchasing  this  CLARKE  Portable  Generator.
Before attempting to use the equipment, please read this manual thoroughly and follow

the  instructions  carefully.  In  doing  so  you  will  ensure  the  safety  of  yourself  and  that  of

others  around  you,  and  you  can  look  forward  to  the  Generator  giving  you  long  and

satisfactory service.

CLARKE  GUARANTEE

This CLARKE product is guaranteed against faulty manufacture for a period

of 12 months from the date of purchase. Please keep your receipt as proof

of purchase.
This guarantee is invalid if the product is found to have been abused or

tampered with in any way, or not used for the purpose for which it was

intended.
Faulty goods should be returned to their place of purchase, no product can

be returned to us without prior permission.
This guarantee does not effect your statutory rights.

Contents

Page No

Guarantee .................................................................................... 2

Safety Precautions ....................................................................... 3

Component  Identification......................................................... 4

Operation ........................................................................ 5,6,7 & 8

Maintenance ............................................................. 8,9,10 &  11

Trouble Shooting ....................................................................... 12

Storage ....................................................................................... 13

Specifications ............................................................................. 13

Wiring Schematic ....................................................................... 14

5. Storage

•

If the generator is to be stored for long periods, proceed as follows.
Drain fuel tank, (fuel left in the tank for long periods will deteriorate causing difficulty

when

trying to start the engine).

•

Drain fuel from the carburettor.

•

Change the engine oil.

•

Wash the air cleaner.

•

Check for loose bolts etc, tighten any found.

•

Check for other defects, any defects should be rectified before continuing.

•

Clean  generator thoroughly and  apply a  preservative  spray if  available.

•

Ensure the engine switch is in the STOP position.

•

Pull the starter handle until resistance is felt, leave in that position.

•

Store indoors in a well ventilated area, preferably with a low humidity level.

WARNING

Observe extreme caution when draining the fuel tank, DO NOT pour fuel down drains etc,

always dispose of fuel, oils and chemicals etc, according to local authority regulations.

6. Specifications

Engine.

Type.

Petrol / Forced air cooled / 4 stroke / Side valve.

Displacement.

92cc (5.61cv.in).

Fuel  Tank  capacity. 1.5 Litres.
Ignition System.

Solid state ignition.

Starting System.

Recoil.

Continuous  Rating.

Approx 3-4 Hours (50Hz).

Generator.

Type.

Type.2 pole revolving field.

Exciting System.

Self-exciting.

Voltage  Regulating

System.

Condenser  type.

AC  Frequency.

50Hz.

AC Voltage.

230 vac.

AC  Max  Output.

700W  50Hz.

AC  Rated  Output.

600W 50 Hz.

DC  Output.

12V  100W.

Over  Current

Protection.

Circuit  breaker.

Dimensions.

L x W x H

365 x 265 x 345mm (14½” x 10½” x 13½”)

Dry Weight.

22.5kg  (49½lbs).

-13-

-2-

Summary of Contents for G900

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS 0704 PORTABLE GENERATOR PORTABLE GENERATOR MODELNO G900 PARTNo 8010100 ...

Page 2: ...hat the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice 7 Schematic 1 14 ...

Page 3: ...eft in the tank for long periods will deteriorate causing difficulty when trying to start the engine Drain fuel from the carburettor Change the engine oil Wash the air cleaner Check for loose bolts etc tighten any found Check for other defects any defects should be rectified before continuing Clean generator thoroughly and apply a preservative spray if available Ensure the engine switch is in the ...

Page 4: ...cleaned up and allowed to dry thoroughly before starting the generator 9 NEVER cover or enclose in box etc 10 NEVER operate the generator indoors 11 NEVER operate the generator when raining or snowing 12 NEVER operate in enclosed area where there is insufficient ventilation such as a tunnel etc ensure the exhaust pipe is directed towards a well ventilated open area 13 NEVER connect the generator t...

Page 5: ...of burnt or deposited carbon Fig 11 Check for correct gap between the electrodes Adjust gap to 0 6 to 0 7mm 0 02 to 0 03 by reforming the electrode Fig 12 Recommended replacement plug type Champion RCJ8 or NGK BMR4A Refit spark plug in reverse order DO NOT overtighten and take extra care not to break or damage the porcelain Porcelain Carburettor Adjustment NOTE It shouldn t be necessary to adjust ...

Page 6: ... a x Level Oil Filler Plug Dipstick Fuel Level Check fuel level before starting the generator by viewing the fuel gauge on top of the generator If the tank requires filling observe all the safety aspects before doing so WARNING Always connect a ground lead to the generator body when refuelling One end of the lead should be connected to the ground terminal below the recoil handle the other to a goo...

Page 7: ...k the oil level and top up as necessary see maintenance section 4 Fig 4 Fig 5 1 Fig 7 2 3 a b c d Air Filter The air cleaner consists of three parts Fig 7 To Clean replace the air filter proceed as follows All parts removed must be carefully put to one side prior to cleaning and reassembling Using No 2 phillips screwdriver loosen anticlockwise and remove the cover securing screw Fig 7a Remove the ...

Page 8: ...reaker button is released If the circuit breaker continually trips out and the cause cannot be traced contact your nearest Clarke dealer for advice alternatively have the connected appliance checked by a qualified electrician To determine if the fault lies with the appliance or the generator itself try connecting another appliance if the breaker still trips out the fault is clearly within the gene...