![Clarke Focus II Operator'S Manual Download Page 33](http://html1.mh-extra.com/html/clarke/focus-ii/focus-ii_operators-manual_2614796033.webp)
ENGLISH
32
Operator’s Manual - FOCUS
®
II L17 - S20 - L20 - L20 Cyl. - BOOST
®
L20
MACHINE WORKING HOUR CHECK
(Only if the machine is equipped with hour meter)
Turn the ignition key (A, Fig. 41) to "I".
1.
Press the switch (B) and read on the hour meter (C) the total
2.
number of working hours (scrubbing/drying) performed by
the machine.
Press the switch (B) again.
3.
Turn the ignition key (A) to "0".
4.
FUSE CHECK/REPLACEMENT
Disconnect the battery connector (A, Fig. 42).
1.
Move aside the recovery water drain hose (B).
2.
Remove the battery charger cable (I, Fig. 43) from the cable
3.
holder (J).
Remove the screws (A) and carefully move aside the panel
4.
(B) by disengaging the grommet (K) from its housing on the
panel (B).
Check/replace the following fuses:
5.
F1 fuse, deck: (40 A)
C)
F2 fuse, vacuum system: (30 A)
D)
F3 fuse, drive system: (30 A) (*)
E)
F4 fuse, signal circuits: (3 A)
F)
F5 fuse, brush/pad-holder release: (20 A)
G)
F6 fuse, pump: (3 A)
H)
Perform steps 1 to 4 in the reverse order.
6.
(*) Only for FOCUS II L17, FOCUS II L20, FOCUS II L20 Cyl.,
BOOST L20
Figure 41
Figure 42
Figure 43