A-10
FM40 ST, FM40 LX - 56091153
2/2015
INSTRUCTIONS FOR USE
A - ENGLISH
TROUBLESHOOTING
Problem
Cause
Action
Motor will not start.
No power.
Switch Lever Safety Lock Button (2) not
depressed
Defective switch / Faulty connection
Check power supply and connection
Depress Switch Lever Safety Lock Button (2)
before activating Switch Levers (3).
Contact an authorized Clarke Dealer.
Motor fails to start / runs sluggish.
Low voltage from excessive length or
undersized extension cord.
Defective start capacitor.
Defective start switch.
Defective start/run capacitor
Defective motor low voltage
Use a 12 Ga extension cord, not to exceed
50’ length.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Fuse / Circuit Breaker repeatedly trips.
Low voltage.
Bad connection.
Defective motor.
Eliminate extension cord. Locate power
source closer to work site. Have voltage
checked by a qualifi ed electrician.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
FM40 ST
FM40 LX
Model Number
56105618
56105620
Electrical
1.5HP - 115V/60Hz
1.5HP - 115V/60Hz
Pad/Brush Speed
3540 rpm
3540 rpm
Pad/Brush Size
14” x 20” (355mm x 508mm)
14” x 20” (355mm x 508mm)
Total Weight (w/cord)
160.5 lbs. (72.8 kg)
171 lbs. (77.5 kg)
Sound Pressure Level (ISO 11201)
69dBA
69dBA
Protection Grade
IPX0
IPX0
Protection Class
Material Composition and Recyclability
Type
% of machine weight
% recyclable
Aluminum
1%
100%
Electrical / motors / engines - misc
38%
70%
Ferrous metals
52%
100%
Harnesses / cables
6%
67%
Liquids
0%
0%
Plastic - non-recyclable
2%
0%
Plastic - recyclable
1%
100%
Polyethylene
0%
0%
Rubber
1%
100%
https://harrissupplyind.com - To Order Parts Call 608-268-8080