background image

INSTALLATION DU GAZ DE PROTECTION

AVERTISSEMENT 

UNE MAUVAISE MANUTENTION ET UN MAUVAIS

ENTRETIEN DES BOUTEILLES DE GAZ

COMPRIMÉ ET DES RÉGULATEURS PEUVENT

ENTRAÎNER DES BLESSURES GRAVES OU LA

MORT!

Fixez toujours les bouteilles de gaz au chariot

de soudage, à un mur ou à un autre support fixe afin

d’éviter qu’elle ne tombe et se brise. Lisez, assurez-

vous de bien comprendre et suivez les consignes de

la section RISQUES DE GAZ SOUS PRESSION ET

D’ÉQUIPEMENT du SOMMAIRE DE LA SÉCURITÉ,

au début de ce guide. Fixez votre bouteille de gaz au

chariot de soudage ou à un autre support fixe.

1. Retirez le bouchon protecteur de la bouteille et véri-

fiez que les fils de branchement du régulateur ne

présentent pas de poussière, saleté, huile ou graisse.

Retirez toute poussière ou saleté à l’aide d’un linge

propre. N’ATTACHEZ PAS VOTRE RÉGULATEUR

SI DE L’HUILE OU DE LA GRAISSE SONT

PRÉSENTS, OU S’IL EST ENDOMMAGÉ.

2. Ouvrez la valve de la bouteille UN MOMENT

SEULEMENT afin d’extraire tout corps étranger

du port de la valve. Ne dirigez jamais le port de

valve de la bouteille ouverte vers vous ou

d’autres personnes.

3. Vissez le régulateur (Clarke, modèle WE6540 –

vendu séparément) dans la valve de la bouteille

et serrez à l’aide d’une clé.

4. Poussez fermement sur le tube de gaz par-

dessus les raccords à barbelure, à l’arrière de la

soudeuse et du régulateur.

5. Fixez chaque extrémité du tube sur les raccords

à barbelure à l’aide des pinces du tube.

VÉRIFICATION DU DÉBIT DE GAZ

AVERTISSEMENT 

UNE MAUVAISE MANUTENTION ET UN MAU-

VAIS ENTRETIEN DES BOUTEILLES DE GAZ

COMPRIMÉ ET DES RÉGULATEURS PEUVENT

ENTRAÎNER DES BLESSURES GRAVES OU LA

MORT. 

Afin de réduire les risques de blessure ou

de mort, tenez-vous toujours sur le côté de la bou-

teille opposé au régulateur lorsque vous ouvrez la

valve de la bouteille, en gardant la valve entre

vous et le régulateur. Ne dirigez jamais le port de

valve de la bouteille ouverte vers vous ou d’autres

personnes. Le non respect de cet avertissement

peut entraîner des blessures graves.

Remarque : 

Si la bouteille est équipée de fils de

branchement de régulateur mâles plutôt que

femelles, vous devrez vous équiper d’un adaptateur

de bouteille de gaz comprimé spécial auprès de

votre fournisseur. L’adaptateur devra être installé

entre votre bouteille de gaz et le régulateur.

-La soudeuse doit être branchée et allumée

pour que fonctionne la de commande de gaz. 

-Afin d’éviter d’endommager votre régulateur,

assurez-vous que sa valve est fermée avant

d’ouvrir la valve de la bouteille.

1. Tournez lentement la valve du cylindre d’un

cran, et ouvrez-la ensuite COMPLÈTEMENT.

2. Appuyez sur la détente du pistolet afin de permet-

tre le débit de gaz. MAINTENEZ LA DÉTENTE

ENFONCÉE. Écoutez et tâtez afin de sentir le

débit de gaz à l’extrémité du pistolet de soudage.

Si votre régulateur ne permet aucun réglage, c’est

qu’il a été configuré en usine pour un débit de 20

pieds cubes à l’heure. Si votre régulateur de gaz

permet de régler le coefficient du débit de gaz,

tournez la clé de réglage dans le sens horaire afin

d’augmenter le débit ou dans le sens antihoraire

afin de le diminuer. Pour la plupart des soudages,

le débit de gaz doit être d’au moins 15 à 20 pieds

cubes à l’heure. Si vous n’entendez ni ne sentez

le gaz, vérifiez toutes les étapes de branchement.

3. Relâchez la détente.

Remarque : Si vous soudez à l’extérieur ou au

vent, il peut être nécessaire d’installer un paravent

afin d’empêcher le gaz de protection d’être soufflé

sur la zone de soudure.

-ASSUREZ-VOUS DE FERMER LA VALVE

DE LA BOUTEILLE DE GAZ UNE FOIS LE

SOUDAGE TERMINÉ.

ALIGNEMENT ET RÉGLAGE DU

DÉVIDOIR

Avant d’installer tout fil de soudage à l’appareil,

une rainure de bonne taille doit être placée sur le

mécanisme du dévidoir.

Figure 8. 

Moteur d’avancement

13

Summary of Contents for Fluxcore/MIG 135sg WE6441

Page 1: ...duct read this manual and follow all its Safety Rules and Operating Instructions Model WE6441 UPC 052249 065371 Clarke Power Products Inc 28740 Glenwood Rd Perrysburg OH 43551 Tel 800 227 9603 or 419...

Page 2: ...ress where product was purchased 3 Your full name street address and telephone number 4 Your Return Authorization Number clearly marked on outside of package Clarke Power Products will not be responsi...

Page 3: ...to install operate or service this welder Failure to comply with these instructions could result in personal injury and or property damage RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Note The follo...

Page 4: ...Do not attempt to plug the welder into the power source if the ground prong on power cord plug is bent over broken off or missing Do not allow the welder to be connected to the power source or attemp...

Page 5: ...an start fires burn skin and damage eyes Do not wear gloves or other clothing that contains oil grease or other flammable substances Do not wear flammable hair preparations Do not touch the hot weld b...

Page 6: ...metals produce EXTREMELY TOXIC fumes which can cause discomfort illness and death Do not weld or cut in areas that are near chlorinated solvents Vapors from chlorinated hydrocarbons such as trichloroe...

Page 7: ...a faulty regulator from service for repair if any of the following conditions exist Gas leaks externally Delivery pressure continues to rise with down stream valve closed The gauge pointer does not m...

Page 8: ...mum welding time allowed The balance of the 10 minute cycle is required for cooling This welder has a duty cycle rating of 40 at the rated output This means that you can weld for 4 minutes out of 10 w...

Page 9: ...ll waste power and heat Scrape away dirt rust scale oil or paint before attaching the ground clamp Ground Cable The ground cable connects the ground clamp to the internal workings of the welder Weldin...

Page 10: ...rs between the welder s power cord and the power source receptacle Make sure the POWER switch is OFF then connect your welder s power cord to a properly grounded 120 Vac 60 Hz single phase 20 amp powe...

Page 11: ...holes of the front foot with the front screw holes on the bottom of the welder The curved face of the front foot should face the front of the welder 3 Insert the two Phillips head screws includ ed in...

Page 12: ...weld puddle which keeps impurities in the air from infecting the weld Inadequate shielding will result in porous brittle welds Although there are many gasses and gas mixtures available for MIG weldin...

Page 13: ...between you and the regulator Never aim the open cylinder valve port at yourself or bystanders Failure to comply with this warning could result in serious personal injury Note If the cylinder you hav...

Page 14: ...e roller for the wire size you are using should be fac ing you Use only the proper size drive roller when using your welder Table 4 indicates which drive roller groove should be used with each wire di...

Page 15: ...ert the leading end of the wire into the inlet guide tube located in the Wire Spool Casing Then push it across the drive roller and into the gun assembly about six inches 11 Line the wire up in the to...

Page 16: ...power source Turn the welder ON Set the VOLTAGE dial to the desired setting The VOLTAGE selector controls the weld heat There are four voltage heat selec tions available on this welder Placing the vol...

Page 17: ...piece connect it to metal that is securely attached to the work piece but not electrical ly insulated from it Make certain this other metal is of equal or greater thickness than that of the workpiece...

Page 18: ...f MIG welder operation and must be done before starting each welding job or whenever any of the following variables are changed heat setting wire diameter or wire type 1 Set up and ground a scrap piec...

Page 19: ...intervals All prac tice welds should be done on scrap metal that can be discarded Do not attempt to make any repairs on valuable equipment until you have satisfied yourself that your practice welds a...

Page 20: ...d joint and is broken into two elements Direction and Speed A solid weld bead requires that the welding gun be moved steadily and at the right speed along the weld joint Moving the gun too fast too sl...

Page 21: ...vel It is performed very much the same as the flat weld except that angle B see HOLDING THE GUN p 19 is such that the wire and therefore the arc force is directed more toward the metal above the weld...

Page 22: ...you will need to prepare the edges of the material to be joined by grinding a bevel on the edge of one or both pieces of the metal being joined When this is done a V is created between the two pieces...

Page 23: ...eld 2 The PUNCH AND FILL METHOD produces a weld with the most finished appearance of the three spot weld methods In this method the arc is direct ed through a hole punched or drilled into the top piec...

Page 24: ...ed with the same diameter as the wire it will be used with Note Due to inherent variances in flux cored welding wire it may be necessary to use a contact tip one size larger than your flux core wire i...

Page 25: ...ALWAYS means the nozzle is shorted but this can be hard to detect through the lens of a welding helmet The following testing method is another way to tell if a nozzle is shorted With the welder unplug...

Page 26: ...26 TABLE 5 TROUBLESHOOTING...

Page 27: ...27 SPOOL GUN WELDER MODEL WE6441 WIRING DIAGRAM...

Page 28: ...28 SPOOL GUN WELDER MODEL WE6441 PARTS LIST...

Page 29: ...29 SPOOL GUN WELDER MODEL WE6441 PARTS DIAGRAM THIS PARTS LIST AND LINE DRAWING ARE FOR REFERENCE ONLY THIS TOOL CAN ONLY BE SERVICED AT AN AUTHORIZED CLARKE REPAIR FACILITY...

Page 30: ...30 SPOOL GUN WELDER MODEL WE6441 GUN PARTS LIST...

Page 31: ...31 SPOOL GUN WELDER MODEL WE6441 GUN PARTS DIAGRAM THIS PARTS LIST AND LINE DRAWING ARE FOR REFERENCE ONLY THIS TOOL CAN ONLY BE SERVICED AT AN AUTHORIZED CLARKE REPAIR FACILITY...

Page 32: ...riginal 2 Le nom complet et l adresse du magasin o le produit a t achet 3 Vos nom adresse et num ro de t l phone 4 Votre num ro d autorisation de retour clairement indiqu l ext rieur de l emballage Cl...

Page 33: ...ervice de cette soudeuse Le d faut de se conformer ces directives pour rait r sulter en des blessures corporelles et ou des dommages la propri t CONSERVER CES DIRECTIVES POUR LA R F RENCE FUTURE Remar...

Page 34: ...ource d alimentation de courant si la broche de la mise la terre de la fiche du cordon d alimen tation est repli e bris e ou manquante Ne pas permettre le branchement de la soudeuse sur la source d al...

Page 35: ...mages aux yeux Ne pas porter de gants ou autres v tements qui sont souill s d huile de graisse ou d autres sub stances inflammables Ne pas utiliser de produits pour les cheveux qui sont inflammables N...

Page 36: ...euvent causer des malaises la maladie et la mort Ne pas souder ou couper dans des endroits rap proch s de solvants chlor s Les vapeurs mis es par les hydrocarbures chlor s telles que le trichlor thyl...

Page 37: ...r imm diatement un r gulateur d fectueux de la bonbonne pour la r paration si une ou l autres des conditions suivantes existe Des fuites de gaz externes La pression du d bit continue de monter avec la...

Page 38: ...e souda ge Le restant du cycle de 10 minutes est n ces saire au refroidissement Cette soudeuse est dot e d un coefficient de cycle de service de 40 la sortie du coefficient Ceci signifie que vous pouv...

Page 39: ...sance et de chaleur liminez toute poussi re rouille tartre huile ou peinture avant d attacher la pince de mise la terre C ble de mise la terre Le c ble de mise la terre branche la pince de mise la ter...

Page 40: ...ntation de la soudeuse et la prise d alimenta tion Assurez vous que le bouton d alimentation est la position OFF lorsque vous brancher le cor don d alimentation de votre soudeuse la source d alimentat...

Page 41: ...nez les ouvertures du pied avant avec les orifices des vis avant sur le dessous de la soudeuse La face courb e du pied avant doit faire face au devant de la soudeuse 3 Ins rez les deux vis Phillips co...

Page 42: ...quate entra ne des soudures poreuses et fragiles Bien qu il existe plusieurs gaz et compos s de gaz disponibles pour le soudage MIG les recomman dations suivantes sont bas es sur les caract ris tique...

Page 43: ...z la valve de la bouteille en gardant la valve entre vous et le r gulateur Ne dirigez jamais le port de valve de la bouteille ouverte vers vous ou d autres personnes Le non respect de cet avertissemen...

Page 44: ...deuse Le tableau 4 indique quelle rainure doit tre utili s e avec chaque diam tre de fil 4 Trouvez la taille de d vidoir appos e corres pondant au diam tre du fil installer voir figu re 10 Enfoncez le...

Page 45: ...ier de la bobine Poussez le ensuite travers le d vidoir et dans le pistolet sur environ six pouces 11 Alignez le fil sur la rainure sup rieure du d vidoir et poussez le bras de tension contre le d vid...

Page 46: ...de TENSION au r glage d sir Le s lecteur de TENSION con tr lent la chaleur de la soudure Il existe 4 s lections temp rature de tension pour cette soudeuse La tension chaleur minimale est atteinte en...

Page 47: ...a pince de mise la terre directement sur la pi ce travailler branchez la au m tal bien fix sur la pi ce sans en tre isol au niveau lectrique Assurez vous que ce m tal ou les autres m taux sont d paiss...

Page 48: ...D ROULEMENT DU FIL Il s agit d une des parties les plus importantes du fonctionnement de la soudeuse MIG qui doit tre effectu e avant chaque ouvrage de soudage ou chaque fois que les variables suivan...

Page 49: ...tes p riodes de pratique intervalles r guliers Toutes les soudures de pratique devraient tre faites sur des pi ces de m tal pou vant tre mises aux rebuts N essayez pas d utili ser des quipements de va...

Page 50: ...mouvement du pistolet le long du joint de soudure Il se divise en deux l ments Sens et vitesse Un cordon de soudure solide exige un d placement stable et la bonne vitesse du pistolet le long du joint...

Page 51: ...voir COMMENT TENIR LE PISTOLET la page 19 est tel que le fil et donc la force de l arc est dirig plus avant sur le m tal au dessus du joint de soudure Ceci aide emp cher le bain de fusion de couler ve...

Page 52: ...le rebord d une des morceaux de m tal joindre Une fois ceci effectu un V est cr entre les deux morceaux de m tal qui sera referm par le soudage Dans la plupart des cas plus d une passe ou cordon doive...

Page 53: ...fectuer une soudure par points 2 La M THODE DE POINTE ET REMPLIS SAGE est la soudure offrant le meilleur fini parmi les trois m thodes de soudage par points Avec cette m thode l arc est dirig vers un...

Page 54: ...soudage tout en lais sant le fil avancer sans heurt Utilisez toujours un tube contact du m me diam tre que le fil utilis Remarque tant donn les variations inh rentes au fil de soudage fourr il peut t...

Page 55: ...ST DE COURT CIRCUIT DE BUSE Un clair entre la buse et la pi ce de m tal signifie TOUJOURS que la buse est court circuit e mais ceci peut tre difficile d tecter travers la lentille d un casque de soude...

Page 56: ...26 TABLEAU 5 D PANNAGE...

Page 57: ...27 DIAGRAMME DE C BLAGE DE LA SOUDEUSE PISTOLET BOBINE WE6441...

Page 58: ...28 LISTE DES PI CES DE LA SOUDEUSE PISTOLET BOBINE WE6441...

Page 59: ...S PI CES DE LA SOUDEUSE PISTOLET BOBINE WE6441 CETTE LISTE DES PI CES AINSI QUE LE SCH MA SONT TITRE DE R F RENCE SEULEMENT CET APPA REIL NE PEUT TRE R PAR QUE PAR LE PERSONNEL D UN CENTRE DE SER VICE...

Page 60: ...30 LISTE DES PI CES DU PISTOLET DE LA SOUDEUSE PISTOLET BOBINE WE6441...

Page 61: ...ES DU PISTOLET DE LA SOUDEUSE PISTOLET BOBINE WE6441 CETTE LISTE DES PI CES AINSI QUE LE SCH MA SONT TITRE DE R F RENCE SEULEMENT CET APPAREIL NE PEUT TRE R PAR QUE PAR LE PERSON NEL D UN CENTRE DE SE...

Page 62: ...120v SPOOL GUN WELDER OPERATING MANUAL Model WE6441 UPC 052249 065371 WE6441 M001 0904...

Reviews: