NOTE:
The most common problem associated with
water pump operation, is leaks on the
SUCTION side of the pump. Even a pin hole
in the inlet hose is sufficient to seriously
reduce or stop altogether, the drawing of
water. Ensure all connections are air tight
and the inlet hose is completely sound.
LED DISPLAY
The unit is equipped with
three LEDs which provide
information as to the
pumps status.
GREEN LED
indicates that
the pump is correctly
connected to the mains
supply, and is ready for
use.
YELLOW LED
indicates
that the pump is operating
normally.
RED LED
indicates that a
problem exists and the
pump is not functioning due
to the following:
Dry running safety device has intervened.
Pump impeller jammed no water flow.
Pumps overload protector has tripped.
Leaks on suction side of pump.
To cancel the red LED, and reset the pump,
press the reset button.
TROUBLE SHOOTING
Pump constantly switches ON and OFF.
This is caused if there are leaks of any kind on
the OUTLET side of the pump. Even a small
leak will be sufficient to keep the pump running
constantly. Ensure ALL connections are water
tight, and that taps etc., do not drip.
It is also possible that
foreign matter has found its
way into the pump. In which
case, disconnect the pump,
and rinse it thoroughly using
a water jet, and clean water.
The pump does not work.
Calcium build up inside
device.
Unplug and disconnect the
pump from the water and
electrical supplys. Fill with
anti-liming agent or a
mixture of water and
vinegar, and leave to soak.
Rinse through thoroughly before re-connecting.
For other possible problems, consult the pumps
Instruction Manual.
SPECIFICATIONS
Power Source .................................................... 230V 50Hz
Operating Range ............................................... 1.5bar - Max. Pump Pressure
Max. Delivery .................................................... 120 l/min (32 gal/min)
Max. Water Temp. ............................................ 35°C
Max Operating Press ........................................ 8 bar
Degree of Protection ......................................... IP44
Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE
International reserve the right to change specifications at any time without prior notice.
For Spare Parts and Servicing, please contact your nearest dealer, or
CLARKE International, on one of the following numbers.
PARTS - 0181 558 6696 SERVICE - 0181 556 4443
PARTS & SERVICE FAX - 0181 558 3622