NOTE:
The most common problem associated with

water pump operation, is leaks on the

SUCTION side of the pump. Even a pin hole

in the inlet hose is sufficient to seriously

reduce or stop altogether, the drawing of

water. Ensure all connections are air tight

and the inlet hose is completely sound.

LED DISPLAY

The unit is equipped with

three LED’s which provide

information as to the

pumps status.

GREEN LED

 indicates that

the pump is correctly

connected to the mains

supply, and is ready for

use.

YELLOW LED

 indicates

that the pump is operating

normally.

RED LED

 indicates that a

problem exists and the

pump is not functioning due

to the following:
•

Dry running safety device has intervened.

•

Pump impeller jammed  no water flow.

•

Pumps’ overload protector has tripped.

•

Leaks on suction side of pump.

To cancel the red LED, and reset the pump,

press the reset button.

TROUBLE SHOOTING

Pump constantly switches ON and OFF.

This is caused if there are leaks of any kind on

the OUTLET side of the pump. Even a small

leak will be sufficient to keep the pump running

constantly. Ensure ALL connections are water

tight, and that taps etc., do not drip.

It is also possible that

foreign matter has found its

way into the pump. In which

case, disconnect the pump,

and rinse it thoroughly using

a water jet, and clean water.

The pump does not work.

Calcium build up inside

device.
Unplug and disconnect the

pump from the water  and

electrical supply’s. Fill with

anti-liming agent or a

mixture of water and

vinegar, and leave to soak.

Rinse through  thoroughly before re-connecting.
For other possible problems, consult the pumps’

Instruction Manual.

SPECIFICATIONS

Power Source .................................................... 230V 50Hz
Operating Range ............................................... 1.5bar - Max. Pump Pressure
Max. Delivery .................................................... 120 l/min (32 gal/min)
Max. Water Temp. ............................................ 35°C
Max Operating Press ........................................ 8 bar
Degree of Protection ......................................... IP44

Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE

International reserve the right to change specifications at any time without prior notice.

For Spare Parts and Servicing, please contact your nearest dealer, or

CLARKE International, on one of the following numbers.

PARTS - 0181 558 6696      SERVICE - 0181 556 4443

PARTS & SERVICE FAX -  0181 558 3622

Reviews: