REAR BLADE
.06
How To Adjust The Squeegee cont.
Adjusting Squeegee Tilt:
The tilt of the squeegee causes the rear blade to raise up
in the center or on the ends, depending on which
direction the tilt is changed. For tilt adjustment, refer to
figure 9. Loosen left and right screw "X". In order to
bring the rear blade down in the center, tip "Y" down. To
bring both ends down, tip "Y" up. Make very small
adjustments and try it until a uniform flare is achieved.
Changing the tilt may also require readjusting the squee-
gee pressure.
Adjusting Squeegee Blades:
When properly installed the front blade should be ap-
proximately .06 above the rear blade. See figure 10.
Adjusting Squeegee Support Wheels:
The support wheels should be set at .12 above the floor
with the rear blade touching the floor. See figure 10.
WARNING: Maintenance and repairs must
be done by authorized person-
nel only .
WARNING: Electrical repairs must be
done by authorized personnel
only.
Consult your Clarke Authorized Service Person to do
the service procedures.
Use only genuine Clarke parts.
How to Clean the Solution Line
If the solution line becomes clogged, follow this procedure:
1. Turn key switch "OFF" and remove the key.
2. Open brush motor cover and remove brush housing.
3. Remove brushes/pads.
4. Locate the solution shut-off valve. It is located behind
the left wheel.
5. Turn solution valve "OFF". See figure 12 (A).
6. Locate the solution filter screen. It is located on the
back of the solution valve. See figure 12 (B).
7. Unscrew the female garden hose connector from the
back of the solution valve. The filter screen is in the
female connector.
8. Remove the filter screen. See figure 11.
9. Clean and replace screen.
10. Attach the female garden hose connector to the
solution valve.
11. Turn solution valve to "ON".
MAINTENANCE
Figure 9
Figure 10
Figure 11