background image

10

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

TROUBLESHOOTING

TECHNICAL SPECIFICATION

Cause

Solution

No operation

 

Power cable disconnected

Insert the plug into a power 
socket.

Water tank is full

Empty the water tank.

Water tank is not seated 
properly.

Replace the tank correctly in 
position.

Air vent closed.

Open the air vent.

Dehumidified 
volume is small

Is the filter dirty?

Clean the filter as specified.

Check to see if the air inlet 
is blocked.

Remove dirt from the air inlet.

The dehumidifier is in ‘air 
clean’ mode.

Change the operation mode 
to the dehumidifying mode.

Operation 
stops during 
spot 
dehumidifying

The room temperature is 
higher than the usable 
operating temperature.

Dehumidifying operation will  
restart automatically when the 
temperature falls

Washed 
clothes are not 
dried 

Clothes are not exposed to 
the air from the unit.

Try to expose the clothes to the 
air flow.

Washed clothes are hard to 
dry when the temperature 
is low.

Check to see if the room 
temperature is too low

Power source

220 to 240 Volts AC 50Hz

Input Power 

400W

Water tank capacity

5 Litres

Weight

13.6 kg

Operation temperature

5 - 35 degrees Celsius

Dimensions (LxWxH)

290 mm x 386 mm x 575 mm

Refrigerant

R134a

Summary of Contents for DH20

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0510 20 LITRE DEHUMIDIFIER MODEL NO DH20 PART NO 6470652 ...

Page 2: ... purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL PROTECTION Recycle unwanted materials instead of dispo...

Page 3: ...es 7 Before cleaning or maintenance operations always unplug the appliance from the power supply 8 Do not move the appliance by pulling the power cable 9 Do not install the appliance in rooms containing gas oil or sulphur Do not install near sources of heat 10 Do not use the appliance on inclined surfaces 11 Keep the appliance at least 50 cm away from inflammable substances alcohol etc or pressuri...

Page 4: ...azard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked L or coloured Red The wire which is coloured Yellow and Green...

Page 5: ...ifier close to a mains supply socket A free space indicated must be left around the dehumidifier so as not to block the air flow Make sure that the power cable is not placed where it can be inadvertently pulled or pinched and where it does not cause a trip hazard NO DESCRIPTION 1 Control panel 2 Handle 3 Air vent 4 Filter cover Air inlet 5 Water tank 3 4 5 2 1 ...

Page 6: ...OMATIC Used to dehumidify a room or prevent a room from getting mouldy through excessive condensation The dehumidifying functions stops when the humidity falls below 60 The air cleaning function continues as long as the unit is switched on CONTINUOUS Used to dehumidify a wardrobe Position the dehumidifier with the air inlet facing the open doors DRY CLOTHES Used to dry a carpet or small space or t...

Page 7: ...e timer function works in ALL modes SWITCHING OFF Press the button to turn the dehumidifier off EMPTYING THE WATER TANK 1 When the FULL indicator on the panel illuminates switch off and disconnect from the mains supply 2 Carefully remove the water tank by placing your fingers in the channel on either side of the tank and pulling forwards as shown opposite 3 Discard the water and refit the water ta...

Page 8: ... opening prise the cover for the drain hose away using a screwdriver 3 Fit the drainage pipe adapter supplied into position shown on the right 4 Put the drain hose not supplied through the hose opening and securely fit the hose to the drainage pipe adapter The hose should have an internal diameter of 15mm and an outer diameter of less than 20mm Make sure that the drain hose always runs downhill aw...

Page 9: ...from the bottom 3 Remove the filter holder 4 Unclip the cage at the rear of the filter holder 5 Wash the filter under running water to remove any dust 6 Allow the filter to dry naturally 7 Refitting is the reverse process The frequency depends on the duration and the level of dust in the enviroment STORAGE Unplug from the mains socket and empty the tank Clean and reinstall the filter Cover the deh...

Page 10: ...e air inlet The dehumidifier is in air clean mode Change the operation mode to the dehumidifying mode Operation stops during spot dehumidifying The room temperature is higher than the usable operating temperature Dehumidifying operation will restart automatically when the temperature falls Washed clothes are not dried Clothes are not exposed to the air from the unit Try to expose the clothes to th...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 12: ......