3 KW HEATERS

The 3kw heater has three settings for 1) fan only, 2) fan plus single heating 
element, 3) fan plus both heating elements. The other control is a progressive 
thermostat which is rotated through 270 degrees. A cutout is used to 
maintaina constant pre-set temperature.

The thermostat will then switch the heater on and off automatically to control 
the room temperature according to the pre-set value, maintaining a constant 
room temperature.

When using the heater to warm a cold room, first turn the thermostat to MAX 
and run the heater on full power until the room temperature reaches the 
required value, then turn the thermostat anti-clockwise until it switches off.

When using the heater for the first time a slight emission of smoke may be 
noticed. This is quite normal and soon stops. It is caused by residual traces of oil 
remaining on the element from production.

After use, turn the thermostat to the OFF position and the selector switch to the 
Fan Only position, and leave the unit to cool down for a couple of minutes.

5KW, 9KW &15KW HEATERS

The 5 & 9kw units have a three-position twist control for FAN only, and FAN plus 
either half or full heat output. The 15kw unit has a four position control;- FAN 
only, FAN + 1/3, FAN + 2/3 & FAN + full heat output. A thermostatic 
temperature control is also provided for fine control of heat output at a 
constant pre-set temperature.

Should the heater overheat, a thermal cutout will operate, shutting down the 
unit. If this happens, allow time for the unit to cool (approx. 10 minutes) before 
pressing the RESET using a suitable tool, and restarting the heater.

When switching the unit OFF, it is recommended that the unit is run in the FAN 
ONLY mode for approx. 10 minutes, to cool the heating elements, before 
switching off completely and finally disconnecting from the mains supply

Summary of Contents for Devil 6003

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0618 rev 8 ELECTRIC FAN HEATERS MODEL NO DEVIL 6003 6005 6009 6015 PART NO 6925220 6925225 6925230 6925235 ...

Page 2: ...ich will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Throu...

Page 3: ...rge control with room and or outdoor temperature feedback n a Electronic heat charge control with room and or outdoor temperature feedback n a Fan assisted output n a Type of heat output room temperature control select one Single stage heat output no temperature control No Two or more manual stages no temperature control No With mechanical thermostat temp control Yes With electronic temperature co...

Page 4: ...er near combustible materials such as curtains furniture etc Allow at least 2 metre clearance DO NOT place the heater on a raised surface or anywhere where it could topple over Take care to ensure that the grille cannot be blocked by curtains or other fabrics Do not operate fan heaters in explosive atmospheres such as in the presence of flammable liquids gases or dust such as in a paint spray boot...

Page 5: ...cover the heater DO NOT touch the heater casing or grille when first switched off as these will be very hot and will take time to cool DO NOT get the heater wet or use in areas of high condensation DO NOT allow the power lead to touch hot surfaces DO NOT connect other appliances to the same mains socket as the heater Only use the heater in an level position Do not use this heater with a programmab...

Page 6: ...er Take immediate action to repair or replace damaged parts Do not allow the heating elements to become covered with dust which could become a fire hazard If used in a dusty workplace it should be cleaned as described under Cleaning and Maintenance Use recommended parts only Unapproved parts may be dangerous and will invalidate the warranty DO NOT attempt to repair a damaged heater contact the Cla...

Page 7: ...ack The BROWN wire must be connected to the terminal which is marked L or coloured Red The YELLOW GREEN wire must be connected to the terminal which is marked E or or coloured Green We strongly recommend that this machine is connected to the mains supply via a Residual Current Device RCD If in any doubt consult a qualified electrician DO NOT attempt any repairs yourself DEVIL 6005 5KW DEVIL 6009 9...

Page 8: ...hold Devil 6003 only or workshop factory use They incorporate a thermostat which detects the temperature of the room air and controls the heater to maintain a pre selected temperature between 0 40 C A manually reset thermal cutout is provided for safety in the event of overheating on the 6005 6009 6015 models The 2kw and 3kw units are fitted with a self resetting thermal cutout The fan motor runs ...

Page 9: ...ed This is quite normal and soon stops It is caused by residual traces of oil remaining on the element from production After use turn the thermostat to the OFF position and the selector switch to the Fan Only position and leave the unit to cool down for a couple of minutes 5KW 9KW 15KW HEATERS The 5 9kw units have a three position twist control for FAN only and FAN plus either half or full heat ou...

Page 10: ... there is any serious build up of dirt wipe thoroughly with a damp cloth Take care that no moisture enters the heater 3 Inspect the mains cable for damage Heat damage will cause the cable to stiffen and crack If this is found have the cable replaced Check the cable routing and ensure it is well away from the heat source 4 Ensure the heating elements are clear of dust use compressed air to clean th...

Page 11: ...orrect power sup ply in accordance with the rating plate label Air inlet grill is blocked Ensure the heater is kept away from any objects which could cover the air inlet or be drawn into it The unit has failed to heat up so only the fan is operating Control switch no set to a heating level Turn switch to HEATING Thermostat has tripped Turn the thermostat and listen If there is no CLICK and the the...

Page 12: ...g 13 Front Grille 2 Top Panel 14 Fan Control KNob 3 Chassis Panel 15 Front Panel 4 Fan 16 Mounting Packer 5 Motor 17 Washer 6 Retaining Clips 18 Control Unit 7 Rear Panel 19 Temp Controller 8 Power Cable 20 Side Panel LH 9 Side Panel RH 21 Air Duct 10 Base Panel 22 Thermal Cut out 11 Heater Bracket 23 Terminal Block 12 Heating Element 1 4kW ...

Page 13: ...IL 6005 1 Support Leg 12 Heating Element 2 Top Panel 13 Front Grille 3 Chassis Panel 14 Fan Control KNob 4 Fan 15 Front Panel 5 Motor 16 Plastic Plug 6 5 Pin Socket 17 Support Bar 7 Rear Panel 18 Control Unit 8 Cable Entry 19 Temp Controller 9 Side Panel RH 20 Side Panel LH 10 Base Panel 21 Heat Shield 11 Heater Bracket ...

Page 14: ...IL 6009 1 Support Leg 12 Heating Element 2 Top Panel 13 Front Grille 3 Chassis Panel 14 Fan Control KNob 4 Fan 15 Front Panel 5 Motor 16 Plastic Plug 6 5 Pin Socket 17 Support Bar 7 Rear Panel 18 Control Unit 8 Cable Entry 19 Temp Controller 9 Side Panel RH 20 Side Panel LH 10 Base Panel 21 Heat Shield 11 Heater Bracket ...

Page 15: ...Leg 13 Front Grille 2 Top Panel 14 Fan Control Knob 3 Chassis Panel 15 Front Panel 4 Fan 16 Heat Shield 5 Motor 17 Closing Plate 6 Angle Bracket 18 Control Unit 7 Rear Panel 19 Temp Controller 8 Cable Entry 20 Side Panel LH 9 Side Panel RH 21 Heater Retainer 10 Base Panel 22 Support Bar 11 Heater Bracket 23 Plug 12 Heating Element 24 Bush ...

Page 16: ...5 350x335x465 Input Wattage kw 1 5 setting 1 3 0 setting 2 2 5 setting 1 5 0 setting 2 4 5 setting 1 9 0 setting 2 95w fan only 5kw setting 1 10kw setting 2 15kw setting 3 Input Amperage 6 4 setting 1 12 setting 2 7 2 13 21 65 Input Voltage 230V 50Hz 400V 50Hz 400V 50Hz 400V 50Hz Fuse Rating 13A 16A 16A 32 A Air Output 512 m3 h 557 m3 h 773 m3 h 1559 m3 h Sound Level 70dB A 70dB A 70dB A 70dB A In...