3 KW HEATERS
The 3kw heater has three settings for 1) fan only, 2) fan plus single heating
element, 3) fan plus both heating elements. The other control is a progressive
thermostat which is rotated through 270 degrees. A cutout is used to
maintaina constant pre-set temperature.
The thermostat will then switch the heater on and off automatically to control
the room temperature according to the pre-set value, maintaining a constant
room temperature.
When using the heater to warm a cold room, first turn the thermostat to MAX
and run the heater on full power until the room temperature reaches the
required value, then turn the thermostat anti-clockwise until it switches off.
When using the heater for the first time a slight emission of smoke may be
noticed. This is quite normal and soon stops. It is caused by residual traces of oil
remaining on the element from production.
After use, turn the thermostat to the OFF position and the selector switch to the
Fan Only position, and leave the unit to cool down for a couple of minutes.
5KW, 9KW &15KW HEATERS
The 5 & 9kw units have a three-position twist control for FAN only, and FAN plus
either half or full heat output. The 15kw unit has a four position control;- FAN
only, FAN + 1/3, FAN + 2/3 & FAN + full heat output. A thermostatic
temperature control is also provided for fine control of heat output at a
constant pre-set temperature.
Should the heater overheat, a thermal cutout will operate, shutting down the
unit. If this happens, allow time for the unit to cool (approx. 10 minutes) before
pressing the RESET using a suitable tool, and restarting the heater.
When switching the unit OFF, it is recommended that the unit is run in the FAN
ONLY mode for approx. 10 minutes, to cool the heating elements, before
switching off completely and finally disconnecting from the mains supply