Clarke Devil 370P Operating & Maintenance Instructions Download Page 5

5

If this appliance is found to be fitted with a plug which is moulded on to the
electric cable (i.e. non-rewireable) please note:

1. The plug must be thrown away if it is cut from the electric cable. There is a

danger of electric shock if it is subsequently inserted into a socket outlet.

2. Never use the plug without the fuse cover fitted.

3. Should you wish to replace a detachable fuse carrier, ensure that the

correct replacement is used (as indicated by marking or colour code).

4. Replacement fuse covers can be obtained from your local Clarke dealer

or most electrical stockists.

FUSE RATING

The fuse in the plug must be replaced with one of the same rating and this
replacement must be ASTA approved to BS1362.

We strongly recommend that this machine is connected to the mains supply
via a Residual Current Device (RCD).

DEVIL 371P & 371SP HEATER UNITS

The 371 models MUST be connected to a 110 Volt, 1 phase 50Hz supply
through a suitably fused isolator switch.  On no account must a 230V, 13amp
(BS1363) plug be used.

NOTE:  If a portable 110V transformer is used, make sure it has a rated

capacity sufficient to take the load of the heater.

In the event that the heater is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.

The user should purchase a suitable connecting lead which is compatible
with the appliance socket. A length of 2-3 metres is recommended as giving
mobility to the heater but without becoming a trip hazard.

If in any doubt, consult a qualified electrician. DO NOT attempt any electrical
repairs yourself.

Summary of Contents for Devil 370P

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS Devil 370P 370SP 371P 371SP Part Nos 6926000 6926005 6926010 6926015 GC0210 DEVIL QUARTZ INFRA RED HALOGEN HEATERS...

Page 2: ...of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in a...

Page 3: ...could become a fire hazard If used in a dusty workplace it should be cleaned as described under Cleaning and Maintenance 9 NEVER touch the halogen tubes for at least 15 minutes after switching off 10...

Page 4: ...reference ELECTRICAL CONNECTIONS DEVIL 370P 370SP HEATER UNITS The 370 models are provided with a 13 amp BS 1363 plug fitted with a 13amp fuse and MUST be connected to a standard 230 Volt 50Hz electri...

Page 5: ...st be ASTA approved to BS1362 We strongly recommend that this machine is connected to the mains supply via a Residual Current Device RCD DEVIL 371P 371SP HEATER UNITS The 371 models MUST be connected...

Page 6: ...ips screwdriver DEVIL 370 371P 1 Attach the four castors to the support legs using the 13mm nuts 2 Attach the legs to the main body using 14mm securing bolts supplied 3 Attach the handles to each side...

Page 7: ...us build up of dirt wipe thoroughly with a damp cloth Take care that no moisture enters the heater Take care NOT to touch the tubes with your fingers Inspect the mains cable for damage Undue heat will...

Page 8: ...a l p e R s w o l b e s u f f I e s u a c e t a g i t s e v n i E K R A L C r u o y t l u s n o c y l d e t a e p e r r e l a e d t e k c o s t a r e w o p o N t e l t u o e l b a t i u s a n i g u l...

Page 9: ...C r e w o P 6 0 0 7 3 V E D G W 6 0 1 7 3 V E D G W 7 d r a u G e r i W 7 0 0 7 3 V E D G W 7 0 1 7 3 V E D G W 8 y l n o P S e m a r F 8 0 0 7 3 V E D G W 8 0 1 7 3 V E D G W 9 e l d n a H c i t s a...

Page 10: ...M P 0 7 3 l i v e D P S 0 7 3 l i v e D P 1 7 3 l i v e D P S 1 7 3 l i v e D o N t r a P 0 0 0 6 2 9 6 5 0 0 6 5 2 9 6 0 1 0 6 2 9 6 5 1 0 6 2 9 6 t h g i e W g k 6 6 1 g k 1 5 1 g k 6 6 1 g k 1 5 1...

Page 11: ...11 DECLARATION OF CONFORMITY...

Page 12: ......