![Clarke DEVIL 1600 User Instructions Download Page 12](http://html1.mh-extra.com/html/clarke/devil-1600/devil-1600_user-instructions_2614851012.webp)
12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
PROBLEM
CAUSE
REMEDY
Motor does not start.
No power.
Check power supply,
power cable and fuse,
and replace if necessary.
Faulty motor/capacitor. Fan
blades bent.
Check & replace if
necessary.
Lock out of appliance due
to overheating. Thermal cut-
out in operation.
Identify cause of over-
heating. Wait for 5 mins
and restart. If condition
persists, contact your
Clarke dealer for advice.
Spark plug does not
spark.
Gap incorrect, faulty
connection
Clean and reset gap if
necessary or replace.
Heater will not ignite
Connection/installation
incorrect.
Check that installation
instructions are followed.
No spark at spark plug due
to loose HT lead or PCB
fault.
Check spark plug wire.
Tighten or re-attach if
loose. If condition persists,
contact your Clarke
dealer for advice.
Heater stops during
operation.
Excessive or insufficient gas
supply.
Check pressure regulator
& replace if necessary.
Check that fan motor
works properly.
Check, and use a larger
cylinder, or two or more in
parallel.
Check there are no
obstructions to air flow.
Check ventilation is
adequate. See also
‘Motor does not Start’.
No gas flow to the
burner.
Cylinder gas tap closed.
Open the gas tap.
Cylinder is empty.
Replace cylinder.
Nozzle is obstructed.
Remove nozzle & clean.
Gas leaks from supply hose
or from tap.
Use soapy water to find
the leak and repair.
Summary of Contents for DEVIL 1600