Clarke CP range User Instructions Download Page 4

FIRE PREVENTION

ALWAYS

 switch the engine OFF when refuelling.

ALWAYS

 refuel away from any source of heat.

ALWAYS

 refuel in a well ventilated area.

NEVER 

overfill fill the tank, fill to the level specified.

NEVER

 smoke whilst refuelling and avoid smoking or using a naked flame

near the generator.

NEVER

 start the engine if there is a fuel spill. Any spillage must be wiped

clean and the generator allowed to dry before attempting to start the engine.

PREVENTION OF ELECTRIC SHOCK

ALWAYS

 store the generator undercover when not in use and away from

damp or wet conditions.

NEVER

 use the generator when it is raining or snowing or in wet or damp

conditions.

NEVER

 operate the generator with wet hands.

NEVER

 use water or any other liquids to clean the unit.

POSITIONING THE GENERATOR FOR USE

ALWAYS

 leave at least a 1 metre gap between the generator and any

surrounding building or structure.

ALWAYS

 ensure the generator is on a solid, flat surface.

ALWAYS

 ensure the surrounding area is free from any material that could

burn or be damaged by heat.

NEVER

 move or tilt the generator whilst it is switched on.

NEVER

 cover or enclose the generator whilst it is in use.

Be aware of the weight of the generator, do not attempt to lift or move the
generator without the assistance of other personnel or suitable lifting equipment.

EXHAUST GAS PRECAUTIONS

WARNING!: EXHAUST FUMES CAN BE FATAL.

ALWAYS

 ensure that there is adequate ventilation when using the generator.

ALWAYS

 position the generator so that the exhaust is pointing away from

people or animals.

NEVER

 use the generator indoors or in a enclosed area. (i.e. in ware house,

tunnel, well or a hold).

- 3 -

Summary of Contents for CP range

Page 1: ...USER INSTRUCTIONS 0706 CP CYB CD Range GENERATOR SET GENERATOR SET ...

Page 2: ...with in any way or not used for the purpose for which is was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights Please Note that details and specifications herein are correct of time of going to print However CLARKE International reserve the right to change specifications...

Page 3: ...d re calibration consult your CLARKE dealer Connect only those appliances whose voltage according to their data plate corresponds to that produced by the generator GENERAL SAFETY PRECAUTIONS ALWAYS use in a well ventilated area ALWAYS ensure the applied load does not exceed the generators rating Overloading the generator is dangerous and could cause serious damage ALWAYS disconnect the generator w...

Page 4: ...y other liquids to clean the unit POSITIONING THE GENERATOR FOR USE ALWAYS leave at least a 1 metre gap between the generator and any surrounding building or structure ALWAYS ensure the generator is on a solid flat surface ALWAYS ensure the surrounding area is free from any material that could burn or be damaged by heat NEVER move or tilt the generator whilst it is switched on NEVER cover or enclo...

Page 5: ...be necessary to achieve the same ampere hour input NOTE Before connecting to the generator ensure the outside of the battery is completely dry Connect the battery as follows 1 Ensure the battery is firmly secured in its compartment within the frame 2 Connect the battery terminals to the battery posts ensuring you connect the POSITIVE connection FIRST When disconnecting ALWAYS disconnect the positi...

Page 6: ...BLES All extension cables from the generator set to the appliance must be carefully selected fitted and maintained Cables in accordance with IEC 245 4 should be used Cables should be inspected regularly and should be replaced not repaired in the event of a defect The length and cross section of conductors should be selected according to the job to be done The table below is an indication of the si...

Page 7: ...output 115V or 230V see fig s 2 3 Depending on the model the switch is mounted as shown or similar to that in fig s 2 3 4 4 With the engine running smoothly connect the appliance to the appropriate receptacle BLUE 230V YELLOW 115V NOTE If the AC circuit is overloaded the circuit protection switch will trip To reset the circuit first disconnect the appliance and rectify the cause of the overload Wa...

Page 8: ...ual for details If the generator is not going to be used for some time the engine must be adequately prepared Please refer to the engine manual for details ELECTRICAL TROUBLE SHOOTING PROBLEM No AC Output CAUSE TROUBLE SHOOTING Selector switch in wrong position Tripped circuit breaker Poor connection or faulty lead Broken AC connector Faulty circuit breaker Set selector switch Reset AC safety trip...

Reviews: