MAINTENANCE
Your sander will operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper care.
Regularly clean the ventilation slots using a soft dry brush or dry cloth. Do not
use any abrasive or solvent-based cleaner.
A damaged power cable should be replaced by your CLARKE dealer or
qualified electrician.
The bearings in this sander are sealed for life and require no maintenance.
FAULTFINDING
SANDER IS OVERHEATING
This indicates the machine is dirty. Clean the ventilation holes and blow out
with compressed air. Always wear eye prodection when using compressed air.
Overloading the machine will also cause overheating. Do not use for heavy
duty work and do not apply excessive pressure.
EXCESSIVE SPARKING OCCURS
This indicates worn brushes. This problem is quickly remedied but you should
consult your CLARKE dealer for parts and advice.
SANDER DOES NOT OPERATE WHEN SWITCHED ON
Check to ensure the fuse is sound and replace if necessary. If the fuse is sound
or blows repeatedly, consult your CLARKE dealer.
POOR ABRASION
If the sander is not removing material efficiently, check the sanding sheet. If
the abrasive is worn down replace the sheet. The sanding sheet must always
be stored in a dry place as if it allowed to become damp, the abrasive
particles will detach from the sheet and will not abrade.
WARNING: BEFORE PERFORMING ANY MAINTENANCE, SWITCH OFF AND
UNPLUG THE SANDER.