8. TROUBLESHOOTING

FAULT

POSSIBLE CAUSE

REMEDY

No AC output - red LED

illuminated

DC input below 10Volts

Recharge or replace battery

Excessive load - thermal

shutdown

Reduce load - wait for

inverter to cool. Turn Off, then

turn On

No AC output

Inverter cold

Disconnect load from

inverter. Operate inverter

without load for a few

minutes. Reconnect load.

No AC output - Green LED
not illuminated

Inverter fuse blown

Remove fuses from their holders

and replace with those of the

same type and rating

Low battery alarm sounds

continuously

Bad wiring connections

Tighten all DC connections

Low battery alarm sounds

Low battery voltage

Recharge battery

Remove load from inverter

and recharge battery

Motorised power tool

won’t start

Excessive start-up load

If appliance does not start,

then appliance is drawing

excessive wattage and will

not work with inverter

-9-

Keep inverter and antenna

distant from each other. Use

shielded antenna cable.

Connect antenna to amplifier

Television/Radio

interference

Snow in picture, buzz in

speaker

9. FUSE REPLACEMENT

If the external fuse blows, then there is most likely a short or overload in the DC wiring. Find
and fix the problem before replacing the fuses. After fuse replacement, reconnect the
inverter, if fuse continues to blow, contact your Clarke dealer, or telephone Clarke
International on 

020 8998 7400

.

This power inverter is equipped with an external fuse. Normally, this fuse will not blow
unless there is a serious problem inside the unit. DO NOT open the unit, there are no user
serviceable parts inside the unit.

Motorised power tool

does not operate at

correct speed

Purely inductive load

Make the load not purely

inductive. Operate an

incandescent lamp at same

time as motor, ensuring the

combined load does not

exceed that of the inverter.

Summary of Contents for CI-1000

Page 1: ...0706 MODEL Nos CI 200 CI 400 CI 600 CI 800 CI 1000 CI 1500 OPERATION MAINTENANCE INSTRUCTIONS 12VDC TO 230VAC INVERTERS 12VDC TO 230VAC INVERTERS...

Page 2: ...LARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is fou...

Page 3: ...an engine compartment inverter MUST be installed in a well ventilated area 5 This inverter is not tested for use with medical devices WARNINGS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK EXPLOSION OR IN...

Page 4: ...cates that the inverter has shutdown from overload over voltage or over temperature 230V Power is provided via a standard 3 pin socket An ON OFF switch turns the inverter circuitry On and Off The swit...

Page 5: ...er than the true voltage when measuring the output of the inverter 4 INSTALLATION 4 1 Power Source Requirements The power source must provide between 11 and 15 volts DC and must be able to supply the...

Page 6: ...the black battery clip to the negative terminal of the battery 3 Connect the red cable to the red post marked on the back of the inverter Connect the red battery clip to the positive terminal of the...

Page 7: ...tarting the appliance Resistive loads are the easiest for the inverter to run However larger resistive loads such as electric stoves or heaters usually require more power than the inverter can deliver...

Page 8: ...drops to 10 volts Start your engine to recharge the battery If the low voltage alarm sounds when the battery is fully charged follow the steps for solving lack of output power in the Troubleshooting...

Page 9: ...is drawing excessive wattage and will not work with inverter 9 Keep inverter and antenna distant from each other Use shielded antenna cable Connect antenna to amplifier Television Radio interference...

Reviews: