Placement of the Inverter

For best operating results, the inverter should be placed on a flat level surface. 3 feet (1.0
meter) cables are provided allowing for easy positioning of the inverter. The inverter should
only be used in locations that meet the following criteria:

DRY 

- Do not allow water and/or other liquids to come into contact with the inverter.

COOL 

- Ambient air temperature should be between -1

O

C (30

O

 F) and 40

O

C, (105

O

F). Do not

place the inverter on or near a heating vent or any piece of equipment which is generating
heat. Keep the inverter away from direct sunlight.

VENTILATED 

- Keep the area surrounding the inverter clear to ensure free air circulation

around the unit. Do not place items on or over the inverter during operation. A fan is helpful
if the inverter is operating at maximum power outputs for extended periods of time. The unit
will shut down if the internal temperature exceeds 65

O

C. The unit will restart after it cools.

SAFE 

- Do not use the inverter near flammable materials or in locations that may accumulate

flammable fumes or gases.

5. OPERATING TIPS

5.1.

Rated Versus Actual Current Draw of Equipment

Most electrical tools, appliances and audio/video equipment have labels that indicate
the power consumption in watts. Be sure that the power consumption of the appliance
you wish to operate is rated at the specified wattage, or less.

The inverter is provided with thermal overload protection. If the temperature increases to
60

O

C, the buzzer will sound for 1 minute, then the unit will shut down, when the temperature

reaches 65

O

C. It will restart once the temperature drops sufficiently. Investigate the cause

of the overload and rectify before restarting the appliance.

Resistive loads are the easiest for the inverter to run. However, larger resistive loads, such as
electric stoves or heaters, usually require more power than the inverter can deliver on a
continuous basis. Inductive loads, such as TV’s and stereos, require more current to operate
than do resistive loads of the same wattage rating. Induction motors, as well as some televisions,
may require 2 to 6 times their wattage rating to start up. The most demanding in this category
are those that start under load, such as compressors and pumps. Testing is the only definitive
way to determine whether a specific load can be started and how long it can run. The unit
will simply shut down if it is overloaded. To restart the unit after a shutdown due to overloading,
disconnect the load and if necessary turn the power switch OFF then ON.

CAUTION: 

This inverter will not operate high wattage appliances.

5.2.

Battery Operating Time

Battery operating time depends upon how much is drawn to operate the particular appliance.
A 120 ampere hour battery for example, can, theoretically, provide 40 amps for a period of 3
hours. However, we recommend that the battery be charged (start the engine) regularly in
order to maintain sufficient output. This will guard against any unexpected shutdown of the
equipment and will ensure that there is always sufficient battery capacity to start the vehicle’s
engine. The inverter will sound its alarm when DC voltage drops to 10.5V.

The inverter may be used whether or not the vehicle’s engine is running. However, the
inverter may not operate while the engine is starting since the battery voltage can drop
substantially during cranking.

In most instances, the inverter can be left connected to the battery when not in use since
it draws little current. However if the vehicle is to remain unused for several days, then
disconnect it from the battery.

-7-

Summary of Contents for CI-1000

Page 1: ...0706 MODEL Nos CI 200 CI 400 CI 600 CI 800 CI 1000 CI 1500 OPERATION MAINTENANCE INSTRUCTIONS 12VDC TO 230VAC INVERTERS 12VDC TO 230VAC INVERTERS...

Page 2: ...LARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is fou...

Page 3: ...an engine compartment inverter MUST be installed in a well ventilated area 5 This inverter is not tested for use with medical devices WARNINGS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK EXPLOSION OR IN...

Page 4: ...cates that the inverter has shutdown from overload over voltage or over temperature 230V Power is provided via a standard 3 pin socket An ON OFF switch turns the inverter circuitry On and Off The swit...

Page 5: ...er than the true voltage when measuring the output of the inverter 4 INSTALLATION 4 1 Power Source Requirements The power source must provide between 11 and 15 volts DC and must be able to supply the...

Page 6: ...the black battery clip to the negative terminal of the battery 3 Connect the red cable to the red post marked on the back of the inverter Connect the red battery clip to the positive terminal of the...

Page 7: ...tarting the appliance Resistive loads are the easiest for the inverter to run However larger resistive loads such as electric stoves or heaters usually require more power than the inverter can deliver...

Page 8: ...drops to 10 volts Start your engine to recharge the battery If the low voltage alarm sounds when the battery is fully charged follow the steps for solving lack of output power in the Troubleshooting...

Page 9: ...is drawing excessive wattage and will not work with inverter 9 Keep inverter and antenna distant from each other Use shielded antenna cable Connect antenna to amplifier Television Radio interference...

Reviews: