OPERATION INSTRUCTIONS

1.

Switch on the power by turning the rotary selector. If the battery
voltage is low, the                symbol will appear and the batteries should
be replaced.

2.

Turn the rotary selector to the required function to be measured.
Choose the highest range when the value to be measured is unknown.

3.

Connect the earth test lead before the positive test lead when
making the connection. Remove the positive test lead first when
disconnecting.

SELECTING RANGES

When the meter is turned on, it will be in the Auto Range mode for
measuring current, voltage, resistance and continuity.

1.

Press the  

RAN 

 button for Manual Range mode. The range will go up

one level at each press and return to the lowest level when the highest
level is reached.

2.

Press the  

RAN 

 button, for two or more seconds to return to the Auto

Range.

3.

Press the  

RAN 

button when measuring the maximum or minimum

value, and the meter will return to the normal working condition.

SELECTING FUNCTIONS

1.

Press the  

SEL 

 button to switch between AC and DC voltage

measurement ranges.

2.

Press the  

SEL  

button to switch between diode and continuity

measuring ranges.

HOLDING READINGS

1.

Press the  

HOLD 

 button to hold the readings while taking

measurements.

The value on the display will be held.

2.

Press the 

HOLD 

button again to release the function.

SELECTING MAXIMUM VALUE

1.

Press the  

MAX 

button to show the maximum value measured.

2.

Press the  

MAX 

 button again to return to standard mode.

Summary of Contents for CDM95

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC0111 PROFESSIONAL AUTO RANGING DIGITAL CLAMPMETER 6 FUNCTION MODEL No CDM95 Part No 4500099...

Page 2: ...rights SPECIFICATION S N O I T A C I F I C E P S T I N U s n o i t p o e g n a R l a u n a M r o o t u A n o i t c e t o r p e g n a r r e v O s e g n a r l l a r o f d e d i v o r P s l a n i m r e t...

Page 3: ...ingReadings 10 SwitchingRanges 10 SwitchingMaximumValue 10 SwitchingFunctions 11 BackLightandClampLightBulbs 11 LowBatteryIndicator 11 AutoPower Off 11 MeasuringACCurrent 12 MeasuringACVoltage 13 Meas...

Page 4: ...pplied to ensure operational safety If necessary they must be replaced with test leads of the same model or class DURING USE 1 Do not take measurements that exceedthe maximum values for this meter 2 D...

Page 5: ...ity 13 To avoid false readings replace the batteries as soon as the Low Battery indicator appears 14 Before use verify the meter operation by measuring a known voltage 15 Never touch exposed wiring co...

Page 6: ...ual ranges are available The meter is equipped with a reading hold function a maximum value measuring function and the function of auto power off COMPONENTS OF THE METER 1 CurrentClamp 2 ClampLighting...

Page 7: ...7...

Page 8: ...8...

Page 9: ...inuity COM Jack Common input connection for current voltage resistance diode and continuity measurement OFF Position For turning off the power Rotary selector For selecting functions and ranges Clamp...

Page 10: ...Range mode The range will go up one level at each press and return to the lowest level when the highest level is reached 2 Press the RAN button for two or more seconds to return to the Auto Range 3 P...

Page 11: ...battery low will appear on the LCD The accuracy of measurement cannot be assured whenthe symbolappears NOTE When the back light is on the Battery Low symbol may appear due to the current drawn causin...

Page 12: ...ments 1 Turn the rotary selector to the A range position 2 Press the RAN button if required to choose the Manual Range mode 3 Squeeze the trigger to open the jaw and fully enclose only one conductor 4...

Page 13: ...n to avoid electric shock when measuring high voltages Do not connect to a voltage greater than 600V rms AC 1 Plug the black test lead into the COM jack and the red test lead into the INPUT jack 2 Tur...

Page 14: ...st leads contact the circuit the true reading will be shown If OL is displayed when in manual mode the measurementhas exceeded the selected range and a higher one should be selected IntheManualRangemo...

Page 15: ...choose the Manual Range mode 4 Connect the leads to the voltage source or load terminals for measurement 5 Take the reading on the LCD The polarity symbol indicates the polarity of the DC voltage sour...

Page 16: ...is outside the selected range and a different one must be selected Using the Manual Range mode when the scale of the value to be measured is not known select the highest range lower the range gradual...

Page 17: ...ircuit resistance ensure the circuit under test has been turned off and that all capacitors have been fully discharged 1 Plug the black test lead into the COM jack the red lead into the INPUT jack 2 T...

Page 18: ...e R y c a r u c c A m h o 0 0 2 m h o 1 0 s t i g i d 2 g d r f o 2 1 m h o k 2 m h o k 1 0 0 0 m h o k 0 2 m h o k 1 0 0 m h o k 0 0 2 m h o k 1 0 m h o M 2 m h o M 1 0 0 0 m h o M 0 2 m h o M 1 0 0...

Page 19: ...gemust be selected It may also mean the circuit is not connected When the input is open OL will appear on the LCD to indicate that the range has been exceeded For measuring resistance above 1 M it may...

Page 20: ...it for measurement 5 If there is continuity in the circuit being tested the buzzer will sound 6 If the test leads are open OL will be displayed on the LCD 2 Turn the rotary selector to the position 3...

Page 21: ...21 Open circuit voltage 0 45V Overload protection 250V DC or rms AC...

Page 22: ...sources of electric current before opening battery cover Loosen the fixing screw on the battery cover and remove it 2 Replace the exhausted batteries with new ones Take care that the polarity of the...

Page 23: ...23 DECLARATION OF CONFORMITY...

Page 24: ......

Reviews: