INSTALLATION
MOUNTING THE UNIT
This filter/regulator is supplied with a
bracket for mounting it to a wall or
any suitable framework.
It should ideally be connected to a
fixed airline or be mounted at the
outlet of the compressor.
1. Secure the bracket to the
regulator using the locking ring.
• Airflow direction is marked with
an arrow on the regulator body.
2. Ensure sufficient free space above the regulator for future adjustments.
3. Ensure the compressor is turned off when making connections. Take care
not to overtighten when connecting the airline unions.
4. After connection, turn on the air supply and check for air leaks. Rectify any
found before starting work.
• PTFE tape may be useful for sealing threaded connections.
SETTING
The adjustment knob is of the locking type.
1. Adjust the delivery air pressure as required, by pulling the regulator cap
upwards and then twisting clockwise to increase or anti-clockwise to
reduce the outlet pressure as displayed on the gauge, When the pressure is
correct, press the cap back to lock and retain the setting.
• Turning the adjustment knob clockwise increases the pressure as
displayed by the gauge. Turning counter clockwise will reduce the
pressure.
• + and - are marked on the knob.
WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR
COMPRESSORS AND COMPRESSED AIR SYSTEMS.