OPERATION & MAINTENANCE
INSTRUCTIONS
LS0214
1” ELECTRIC WATER PUMP
MODEL NO: BIP1500
PART NO: 7230335
Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0214 1 ELECTRIC WATER PUMP MODEL NO BIP1500 PART NO 7230335...
Page 2: ...ld be avoided Your CLARKE water pump has been designed to give long and trouble free service If however having followed the instructions in this booklet carefully you encounter problems take the unit...
Page 3: ...properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest per...
Page 4: ...platform to protect it from flooding Some kind of anti vibration mounting is also desirable Always ensure there is adequate air circulation around the motor The pump should be installed in a dry well...
Page 5: ...terminal to the earth wire and make sure that it is correctly connected to the earth terminal The ring terminal should be placed between the two washers and the screw suitably tightened FITTING THE P...
Page 6: ...d to any water source depending upon the installation layout and the discharge outlet should be directed as required The diameter of the inlet outlet connectors is 1 BSP 25 4 mm Therefore hoses with t...
Page 7: ...water and can assist in priming the pump Protect the pump and pipework from freezing with the addition of suitable lagging The formation of ice may cause serious damage SUCTION LIFT OR GRAVITY FEED T...
Page 8: ...cted a priming hole and threaded plug are provided adjacent to the outlet as shown NOTE As the priming hole is quite small it is recommended to fill the inlet pipe with water before connecting to the...
Page 9: ...urn valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor ma...
Page 10: ...or whenever there is danger of freezing always drain the pump body If the pump has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both insid...
Page 11: ...ear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Ch...
Page 12: ...n loss of flow Blockage of inlet pipe Check pipeline for blockage Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...
Page 13: ...Input Current Maximum Head 3 56 A Outlet Thread Size 1 BSP Weight 8 6 kg Length x Width x Height 298 x 140 x 196 mm Sound Pressure Level 65 dB LpA Sound Power Level 77 dB LwA Guaranteed Sound Power Le...
Page 14: ...150019 5 Motor Front Cover ZGBIP150005 20 Terminal Box ZGBIP150020 6 Ball Bearing ZGBIP150006 21 Power Switch ZGBIP150021 7 Motor Rotor ZGBIP150007 22 Terminal Box Cover ZGBIP150022 8 Stator Coil ZGBI...
Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...
Page 16: ......