 CONTROLS and MACHINE FEATURES

The Vacuum Motor Switches 

See Figure 1-A

The vacuum motor switches are located on the top of the
machine.

The Switch To Activate The Pump

 See Figure 1-B

The switch to start/stop the pump motor is on the top of the
machine. Press the lever on the floor tool to start the
solution flow.  Release the lever on the floor tool to stop the
solution flow.

NOTE

While the B

EXT-

150 machine is in operation,

the pump will shut-off automatically when it reaches
full pressure.  The pump will automatically turn on
when the pressure decreases.

The Float Shut-Off

 

-

See Figure 1C

The float shut-off is in the recovery tank.  When the liquid
raises the float, the air stops moving through the machine.

NOTE: To avoid vacuum motor damage, always
inspect the float filter and ball.  Verify ball travels
easily prior to use of unit.  

See Figure 2

The Vacuum Hose Connector

 See figure 1D

The vacuum hose connector is on the front of the unit.

The Solution Hose Connector

 See Figure 1E

The solution hose connector is on the lower part of the
extractor, below the vacuum hose connector.

The Recovery Tank

 See Figure 1F

The recovery tank is in the top of the machine.

The Solution Tank

 See Figure 1G

The solution tank is in the top of the machine next to the
recovery tank.

Electric Circuit Locator

 See Figure 1H

This unique, patented "smart system", operated by a solid
state circuit, will inform the operator when the two cords
are plugged into separate circuits by illuminating the
"Locator" indicator light.  This helps prevent tripping circuit
breakers.

NOTE: Ground plug on the cord is required to allow
circuit locator to operate correctly.  The system will
not function without proper ground.

The Machine Power Cord (Red "H")

 See Figure 1I

This cord powers all machine functions except the heater.

The Heater Power Cord

 See Figure 1J

This cord powers heater only.

Figure 1

1G

1H

1B 1A

1C

1F

1E

1D

Figure 1

1I

1J

Figure 2

Summary of Contents for BEXT 100

Page 1: ...chine before using it If your operator s cannot read English have this manual explained fully before attempting to operate this machine Si Ud o sus operadores no pueden leer el Ingl s se hagan explica...

Page 2: ...uctions 22 How to Clean an Area of Carpet 22 How To clean a Larger Area of Carpet 22 Maintenance 24 After Each Use of the Machine 24 HowtoPreventDamagefromFreezingTemperatures 26 The Pump and Vacuum M...

Page 3: ...e To reduce the risk of an electric shock use only on a carpet that has been moistened by a cleaning process Protect the machine from rain Keep the machine in a dry building Always clean the machine w...

Page 4: ...Cable 25 ft 12 3 hosp 2 25 ft 12 3 hosp grade plug grade plug Wheels 2 8 non marking 2 3 casters 2 10 non marking 2 2 casters Hose 15 ft crushproof vacuum and high pressure solution line Low Moisture...

Page 5: ...it See Figure 2 The Vacuum Hose Connector See figure 1D The vacuum hose connector is on the front of the unit The Solution Hose Connector See Figure 1E The solution hose connector is on the lower part...

Page 6: ...the detergent of your choice Mix well Although this machine is designed to supply instant hot water the addition of warm or hot water to the holding tank is beneficial and will reduce pre heat times...

Page 7: ...ols can leak onto the carpet and cause light spots or stains NOTE To order Clarkare Extractor Concentrate order part no 398421 To order Clarkare Defoamer order part no 398420 For instructions for prep...

Page 8: ...HT MODE 6 The light will only illuminate when the heater uis heating and will turn off when it reaches operating temperature Figure 7 BEXT 300 HV Control Panel 4 HEAT MODE LOCATOR 5 6 CARPET 3 4 5 VAC...

Page 9: ...ING To prevent possible electric shock protect the machine from rain Keep the machine in a dry building WARNING To prevent possible electric shock always use a 3 wire electrical system connected to th...

Page 10: ...Vacuum only after cleaning each area for maximum water removal Area 1 See figure 8 MACHINEOPERATINGINSTRUCTIONS Aspiration seulement apr s nettoyage de chaque zone pour une limination maximum de l ea...

Page 11: ...nce flushthemachinewith clearwaterattheendofeachworkingday Once a month minimum run a flushing compound through the machine to cut any alkaline build up that may have formed 5 Lubricatewheels casters...

Page 12: ...ery pail 6 Press the lever on the floor tool to activate the pump 7 Make sure the solution runs through the system 8 Release the lever on the floor tool to stop the pump 9 Flush the antifreeze solutio...

Page 13: ...surface of the commutator See A in figure 11 b Uneven color Look for an even dark brown color Clean areas or very dark areas indicate a problem See B in figure 11 c High mica The mica insulation must...

Page 14: ...solution tank 13 Clean the screen 14 Contact an authorized service person 1 Contact an authorized service person 1 Clean the float Replace if damaged 2 Put defoamer in the solution Order P N 398420 3...

Page 15: ...Clarke BEXT 100 100H 150H 300HV Operator s Manual Page 33 BEXT 100 100H 150H 300HV Extractor Section II Parts and Service Manual 70416A...

Page 16: ...Page 34 Clarke BEXT 100 100H 150H 300HV Operator s Manual Clarke BEXT 100 120V Assembly Drawing 7 06...

Page 17: ...Finish 3 29 80334A Washer Flat 3 30 80338A Bolt 20 x 5 3 31 53897A Manifold Vac Motor Black 1 32 52672A Exhaust Flange 1 Ref Part No Description Qty 34 80335A Lock Nut 20 8 39 53885A Quick Disconnect...

Page 18: ...Page 36 Clarke BEXT 100 100H 150H 300HV Operator s Manual Clarke BEXT 100H 120V Assembly Drawing 7 06...

Page 19: ...80334A Washer Flat 3 30 80338A Bolt 20 x 5 3 31 53897A Manifold Vac Motor Black 1 32 52672A Exhaust Flange 1 Ref Part No Description Qty 34 80335A Lock Nut 20 8 39 80340A Quick Disconnect Male PT 1 4...

Page 20: ...Page 38 Clarke BEXT 100 100H 150H 300HV Operator s Manual Clarke BEXT 150H 120V Assembly Drawing 11 05 8A 86 8...

Page 21: ...30 85742A Screw 20 6 31 87026A Washer 6 32 33 170030 Hosebarb 1 34 35 36 37 38 52671A Handle Lifting 1 Items 6 7 86 must be ordered as a set when replacing any original 6 Adapter and 3 85522A Screws 1...

Page 22: ...91 99 86 100 101 97 91 97 23 29 98 89 90 95 103 96 22 91 86 85 84 87 85 88 91 89 91 24 23 92 90 35 77 76 76A 75 63 63A 62 3 2 91 53 54 57 56 55 49 91 52 94 29 93 53 36 37 46 59 58 64 61 68 47 63 65 6...

Page 23: ...A Hinge Rod x 3 SS 2 62 52679A Cord Wrap 2 63 170915 Screw 1 40 20 x 1 SS 2 63A 87026A Washer SS 2 64 61338A Axle 18 1 65 52673A Louver 3 1 66 30635A Gasket Base 67 40750A Housing Lower 68 52470A Cast...

Page 24: ...embly 1 3 59230A RM 8P Tool Assembly 1 4 61393A RM 12M Tool Assembly 1 4A 30496A Hose Asm Squeegee 1 5 59232A Hide A Hose 10 1 6 59228A RM 4M Tool Assembly 1 7 398426 Defoamer 1 case 8 398425 Extracto...

Page 25: ...tion 1 1B 52544A ValveBody 1 1C 52996A Nozzle Spray 2 2 52469A Hose 15 1 3 52833A Tool 3 HP 1 4 398426 Defoamer 1 case 5 398425 Extractor Concentrate 1 case 6 398427 Traffic Lane Spot Cleaner 1 case 7...

Page 26: ...ValveBody 1 1C 52996A Nozzle Spray 2 2 52469A Hose 15 1 3 52833A Tool 3 HP 1 4 398426 Defoamer 1 case 5 398425 Extractor Concentrate 1 case 6 398427 Traffic Lane Spot Cleaner 1 case 7 52953A GeneralP...

Page 27: ...FAN SW SW BLACK BLUE WHITE VAC 2 VAC 1 SW ORANGE ORANGE WHITE BLACK GROUND WHITE VACUUM VACUUM PUMP CORD 1 BLACK HEATER TC CIRCUIT BOARD BYPASS SWITCH WHITE BLACK DUAL CORD SENSOR LOCATOR LIGHT BLACK...

Reviews: