DISCONNECTING THE AIR SUPPLY
Do not disconnect the air supply hose until the air supply has been shut down
and the compressed air released.
1. Refer to the compressor instruction manual for the procedure to shut down
and release the compressed air.
2. Once the pressure has been released, disconnect the air supply hose from
the air drill.
Store the tool safely in its box in a dry, secure environment.
MAINTENANCE
DAILY
1. Before use, drain water from the compressed air supply.
2. Pour a few drops of CLARKE airline oil, into the air inlet. This should be
carried out regardless of whether or not an in-line mini oiler is used. If an
inline mini oiler is not used, this procedure should be repeated after every
two to three hours of use.
WEEKLY
1. Check the air inlet screen filter for
blockage and clean if necessary.
1. Keep the body of the tool clean
and free from debris. Grit or gum
deposits in the tool may reduce
efficiency.
WARNING: MAKE SURE THAT THE DRILL IS DISCONNECTED FROM THE AIR
SUPPLY BEFORE STARTING ANY CLEANING, OR MAINTENANCE
PROCEDURES.