OPERATING INSTRUCTIONS
IMPORTANT: Only use sockets designed for use with a ratchet wrench;
- either
3/8" (10mm) for the CAT109 or 1/
2” (13mm) for the
CAT108.
1
Select the socket you require.
2. Press the socket until it clicks into
place on the square drive.
3. Place the socket over the subject
nut.
•
Take care that the socket is firmly
engaged on the nut to be
tightened or removed.
4. Squeeze the trigger against the
body of the tool to start as in Fig
2.
5. Release the trigger to stop the
tool.
6. Always ensure the tool has
stopped before putting it down.
7. To change the direction, twist the
control at the tip of the tool to
either ‘F’ for forward or ‘R’ for
reverse as in Fig 3.
DISCONNECTING THE AIR SUPPLY
1. Do not disconnect the air supply hose until the compressor has been shut
down and the compressed air pressure released.
2. Once the pressure has been released, disconnect the air supply hose from
the tool.
STORAGE
1. Store the tool safely in its box in a dry, secure environment.
2. If the tool is not to be used for longer than 24 hours, run a few drops of
CLARKE airline oil into the air inlet and run the tool for a few seconds to
ensure that the oil has been well distributed throughout the tool.
3. When storing, ensure the blanking plug is replaced on the airline
connector once the airline has been disconnected.