12
MAINTENANCE
CLEANING THE NOZZLE
If the nozzle becomes clogged with foreign materials such as dirt or calcium,
excessive pressure may develop. If the nozzle becomes partially clogged or
restricted, the pump pressure will pulsate, clean the nozzle immediately by
following the instructions below:
1. Turn off the power washer and
turn off the water supply.
2. Pull trigger to relieve any water
pressure.
3. Disconnect the lance from the
gun.
4. Remove any obstructions with the
nozzle cleaning tool provided.
5. Direct water supply into the end
of the lance for 30 seconds to back flush loose particles.
6. Reconnect the lance to gun and turn on water supply.
CLEANING THE WATER INLET FILTER
This filter should be checked periodically and cleaned if necessary.
1. Remove filter from the water inlet
of the pump as shown.
2. Clean the filter by flushing both
sides with water.
3. Replace the filter into the water
inlet.
• Cone side faces in.
NOTE:
Do not operate power
washer without filter properly
installed.
WARNING: THE MACHINE SHALL BE DISCONNECTED FROM ITS POWER
SOURCE BY REMOVING THE PLUG FROM THE SOCKET-OUTLET DURING
CLEANING OR MAINTENANCE AND WHEN REPLACING PARTS.