11
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
SPECIFICATIONS
Fuse blows or
circuit breaker
trips when
pump starts
1. Motor may be defective.
2. Fuse size is wrong or circuit breaker may be too small
3. Pump clogged. Raise pump and clean impeller
Pump stops
running
1. Thermal overload has operated. Leave for 5-10 minutes
and try again.
2. Pump has run dry, or float switch has cut in.
3. A foreign object has jammed the impeller.
Feature
PSV3A
PSV4A
PSSV2A
PVP11A
Outlet Tread Dia
1
½
”
BSP
1
½
”
BSP
1
½
”
BSP
1
½
”
BSP
Outlet Size
38mm
38mm
38mm
34mm
Voltage
230 Vac
230 Vac
230 Vac
230 Vac
Motor Wattage at Max flow-
rate
400 W
750 W
900 W
1100 W
Fuse Rating
13 amp
13 amp
13 amp
13 amp
Cable Length
10 m
10 m
10 m
10 m
IP Rating
IPX8
IPX8
IPX8
IPX8
Maximum Head Height
5 M
8 M
8 M
11 M
Maximum Depth
7 m
5 m
5 m
5 m
Maximum Flow
133 l/min
216 l/min
208 l/min
258 l/min
Maximum Water Temperature
35
o
C
35
o
C
35
o
C
35
o
C
Maximum Particle Size
5 mm
5 mm
5 mm
5 mm
Weight
4.15 kg
5.15 kg
6.25 kg
6.95 kg
PROBLEM
SOLUTION
Summary of Contents for 7236042