CONTROLS AND DISPLAYS
No
Name
Description
1
FAILURE
1. Light ON = lack of water
2. Light OFF = water supply normal
3. Twinkling light means lack of water. The pump will
stop and re-start.
2
PUMP
1. Light ON = pump working
2. Light OFF = pump will stop
3
AUTO
1. Light ON shows AUTO mode running (no need to
set starting pressure
2. Light OFF = Normal Mode (starting pressure set by
the user
4
POWER
Light ON = System power supply normal
5
Display
1. “000” means real time pressure
2. “L00” means the starting pressure value
3. “P” = Over-pressure protection
6
“+” button
Press button to Increase the pressure setting
7
SET
Change between
Automatic mode and Normal mode
8
“RUN”
Press to manually re-start the pump
9
“-” button
Press button to decrease the pressure setting
Summary of Contents for 7230699