Clarke 7230699 Operation & Maintenance Instructions Manual Download Page 6

6

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

WIRING CONNECTIONS

CONNECTING THE EPC1200 CONTROLLER TO DIFFERENT PUMPS

Summary of Contents for 7230699

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC06 22 ELECTRONIC PUMP CONTROLLER MODEL NO EPC1200 PART NO 7230699...

Page 2: ...pumps by instantly sensing water usage and automatically starting or stopping the pump 2 It protects the pump from running dry The EPC1200 controller has a built in safety circuit which switches the...

Page 3: ...he faulty set starting pressure and the head of the pump In Manual mode the starting pressure can be set between 0 5 and 6 0 bar SPECIFICATIONS SAFETY PRECAUTIONS 1 DO NOT attempt to modify or alter t...

Page 4: ...r must be installed in an upright position as shown by the direction arrows on the label The vertical distance between the highest taps and the controller outlet being no more than shown in the table...

Page 5: ...7400 E mail Parts clarkeinternational com or Service clarkeinternational com MECHANICAL INSTALLATION You should always fit a non return valve to the suction line A foot valve and filter are available...

Page 6: ...6 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING CONNECTIONS CONNECTING THE EPC1200 CONTROLLER TO DIFFERENT PUMPS...

Page 7: ...is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recommend that this product is connected to the mains supply...

Page 8: ...ight OFF pump will stop 3 AUTO 1 Light ON shows AUTO mode running no need to set starting pressure 2 Light OFF Normal Mode starting pressure set by the user 4 POWER Light ON System power supply normal...

Page 9: ...e press RUN and SET at the same time If the display shows P blinks it means the pump will restart in 30 minutes If the failure light blinks it means the pump will restart after 1 minute 30 minutes or...

Page 10: ...the problem 3 Switch on the controller at the mains and press the AUTO button The most common problems associated with water pump operation are leaks on the SUCTION side of the pump Even a pin hole in...

Page 11: ...al PCB is broken Voltage is less than 200 v Pump jammed Cables incorrectly connected The pump does not stop Internal PCB is broken Check valve is stuck Water contains materials in suspension Pipeline...

Page 12: ...of any surface mounted water pump or the delivery side of a submersible pump 25mm 1 diameter 90 threaded female hose adaptor An optional pump filter and cartridge for use with the various Clarke water...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Page 15: ...chase no product can be returned to us without prior permission This guarantee does not effect your statutory rights No Description No Description 1 Nameplate 20 Main housing 2 Screw 21 Check valve ba...

Page 16: ......

Reviews: