GENERAL SAFETY PRECAUTIONS 

Before using this equipment it is in your own interest to read and pay attention 
to the following safety rules.

1.

ALWAYS 

keep the working area clean and well lit. Floors should always be 

kept clear. Cluttered or dark areas invite accidents.

2.

NEVER 

over-reach. Keep your proper footing and balance at all times 

when installing or maintaining the pump.

3.

NEVER 

direct any water discharge towards electrical wiring or equipment.

4.

ALWAYS 

thoroughly familiarise yourself with this pump & its operation, and 

follow all instructions in this manual.

 

Never allow persons unfamiliar with 

these instructions to instal or operate the pump.

5.

ALWAYS 

ensure that the pump is properly installed to prevent it from 

moving during operation, and that the immediate area surrounding the 
pump is kept clear.

6.

ALWAYS

 maintain the pump with care and keep it clean for best / safest 

performance.

7. 

NEVER 

use this product if any part is damaged. Have it inspected and 

repaired by your local Clarke dealer. Always turn the pump off before 
carrying out any maintenance.

8.

NEVER 

modify this pump in any way. Use it ONLY for the purpose for which it 

is designed.

9.

NEVER 

use for pumping flammable liquids or corrosive chemicals. This 

pump is designed to pump clean water only.

11.

ALWAYS 

have the pump serviced by your local Clarke dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

12.

NEVER 

allow the pump to run dry.

WARNING: ALWAYS CONNECT THE PUMP TO AN EARTHED POWER SUPPLY 
VIA AN RCD.

CAUTION: THIS PUMP IS NOT A SUBMERSIBLE PUMP. ON NO ACCOUNT 
SHOULD IT EVER BE IMMERSED IN WATER.

Summary of Contents for 7230330

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0521 REV 5 1 ELECTRIC WATER PUMP MODEL NO BIP1000 PART NO 7230330...

Page 2: ...ld be avoided Your CLARKE water pump has been designed to give long and trouble free service If however having followed the instructions in this booklet carefully you encounter problems take the unit...

Page 3: ...properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest per...

Page 4: ...t platform to protect it from flooding Some kind of anti vibration mounting is also desirable Always ensure there is adequate air circulation around the motor The pump should be installed in a dry wel...

Page 5: ...ire is correctly connected to the earth terminal The bare earth wire should be wrapped around the body of the screw positioned between the two washers and the screw suitably tightened FITTING THE PLUG...

Page 6: ...ed to any water source depending upon the installation layout and the discharge outlet should be directed as required The diameter of the inlet outlet connectors is 1 BSP 25 4 mm Therefore hoses with...

Page 7: ...water and can assist in priming the pump Protect the pump and pipework from freezing with the addition of suitable lagging The formation of ice may cause serious damage SUCTION LIFT OR GRAVITY FEED T...

Page 8: ...ted a priming hole and threaded plug are provided adjacent to the outlet as shown NOTE As the priming hole is quite small it is recommended to fill the inlet pipe with water before connecting to the p...

Page 9: ...urn valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor ma...

Page 10: ...If the pump has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both inside and out It should then be drained and covered over if not already...

Page 11: ...ear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Ch...

Page 12: ...loss of flow Blockage of inlet pipe Check pipeline for block age Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Page 13: ...z Input Wattage Maximum Head 383 W Input Current Maximum Head 1 66 A Outlet Size 1 x 1 25 4 x 25 4 mm Outlet Thread Size 1 BSP Weight 5 2 kg Depth x Width x Height 250 x 122 x 150 mm Sound Pressure Le...

Page 14: ...able Clamp 3 Impeller 18 Terminal Block 4 Screw M5 19 Seal 1 5 Motor Front Cover 20 Capacitor 8uf 6 Ball Bearing 6201 Z2 21 Screw M4 7 Motor Rotor 22 Terminal Cover 8 Motor Stator Coil 23 Connecting W...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......