Clarke 7230330 Operation & Maintenance Instructions Manual Download Page 1

OPERATION & MAINTENANCE

INSTRUCTIONS

   ORIGINAL INSTRUCTIONS                                                  GC0521 - REV 5

1” ELECTRIC WATER PUMP

MODEL NO: BIP1000

PART NO: 7230330

Summary of Contents for 7230330

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0521 REV 5 1 ELECTRIC WATER PUMP MODEL NO BIP1000 PART NO 7230330...

Page 2: ...ld be avoided Your CLARKE water pump has been designed to give long and trouble free service If however having followed the instructions in this booklet carefully you encounter problems take the unit...

Page 3: ...properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest per...

Page 4: ...t platform to protect it from flooding Some kind of anti vibration mounting is also desirable Always ensure there is adequate air circulation around the motor The pump should be installed in a dry wel...

Page 5: ...ire is correctly connected to the earth terminal The bare earth wire should be wrapped around the body of the screw positioned between the two washers and the screw suitably tightened FITTING THE PLUG...

Page 6: ...ed to any water source depending upon the installation layout and the discharge outlet should be directed as required The diameter of the inlet outlet connectors is 1 BSP 25 4 mm Therefore hoses with...

Page 7: ...water and can assist in priming the pump Protect the pump and pipework from freezing with the addition of suitable lagging The formation of ice may cause serious damage SUCTION LIFT OR GRAVITY FEED T...

Page 8: ...ted a priming hole and threaded plug are provided adjacent to the outlet as shown NOTE As the priming hole is quite small it is recommended to fill the inlet pipe with water before connecting to the p...

Page 9: ...urn valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor ma...

Page 10: ...If the pump has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both inside and out It should then be drained and covered over if not already...

Page 11: ...ear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Ch...

Page 12: ...loss of flow Blockage of inlet pipe Check pipeline for block age Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Page 13: ...z Input Wattage Maximum Head 383 W Input Current Maximum Head 1 66 A Outlet Size 1 x 1 25 4 x 25 4 mm Outlet Thread Size 1 BSP Weight 5 2 kg Depth x Width x Height 250 x 122 x 150 mm Sound Pressure Le...

Page 14: ...able Clamp 3 Impeller 18 Terminal Block 4 Screw M5 19 Seal 1 5 Motor Front Cover 20 Capacitor 8uf 6 Ball Bearing 6201 Z2 21 Screw M4 7 Motor Rotor 22 Terminal Cover 8 Motor Stator Coil 23 Connecting W...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...