Clarke 7230096 Operation & Maintenance Instructions Manual Download Page 8

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

TROUBLESHOOTING

If this does not solve your problem, please contact the Clarke service 
department.

PROBLEM

SOLUTION

PUMP WILL 
NOT START

1. Make sure that the power is switched on.

2. Check fuse (consult an electrician if in doubt).
3. If extension lead is fitted, check connections (consult an 

electrician if in doubt).

4. Internal thermal cut-out has not re-set. Leave for 5-10 

minutes and try again.

5. The impeller may be jammed. Disconnect from the mains 

supply and remove any objects that may be obstructing 
the impeller.

6. Float switch may be jammed against side wall, or 

prevented from moving.

7. Water level too low - float switch in OFF position - lift float 

to check switch.

8. If the pump still fails to start, consult your CLARKE dealer. 

PUMP WILL 
START BUT NOT 
PUMP

1. Check that the inlet is not blocked.
2. Check that the discharge tube is not clogged or 

obstructed.

3. The head may be too great, i.e. you are trying to lift the 

water too great a distance for the pump to cope with. 
(“When the pump is not being used for extended periods, 
clean and dry it thoroughly and store in indoors. if the 
pump is left in water, it must be run at least once a week 
to prevent it from seizing up.” on page 7).

4. Air bubble in the pump, produced during immersion.  

Immerse the pump again, at an angle, and shake it whilst 
lowering to remove any air trapped in the system.

5. Impeller may be damaged - Consult your CLARKE dealer.

PUMP WILL 
NOT STOP

1. Float switch may be prevented from moving to the fully 

down position.

2. Float switch may be faulty. Consult your CLARKE dealer 

for advice.

PUMP STOPS 
RUNNING

1. Thermal overload has operated. Leave for 5-10 minutes 

and try again.

2. Pump has run dry, or float switch has cut in.

3. A foreign object has jammed the impeller.

Summary of Contents for 7230096

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC1221 ISS 5 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE PUMP MODEL NO SWP900A PART NO 7230096...

Page 2: ...red with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guar...

Page 3: ...and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 DO NOT pump explosive...

Page 4: ...national com or Service clarkeinternational com OVERVIEW Remove all packaging and make sure that the unit contains no visible damage Dispose of all packaging appropriatly 1 FLOAT SWITCH 4 HANDLE 2 WAT...

Page 5: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the ter...

Page 6: ...ins plug to a high sensitivity residual current device RCD which has a tripping current of less then 30mA 4 Switch the mains power supply on The pump will begin to drain water As the water level falls...

Page 7: ...bris from around the impeller NOTE Do not attempt to repair the pump yourself as you may damage the waterproof seal and invalidate your guarantee Repairs must be carried out by your CLARKE dealer or c...

Page 8: ...ur CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 10: ...over 3 Footing 15 Screw 27 O Ring 4 Casing Cover 16 Mechanical Seal 28 Upper Motor Cover 5 O Ring 17 O Ring 29 Gland Cover 6 Screw 18 Rotor 30 O Ring 7 O Ring 19 Motor Frame 31 Screw 8 Casing 20 Beari...

Page 11: ...in 1 3 Diameter 26 piece assorted hose clip set in various sizes Including 8 x16mm 6 x 22mm 4 x 25mm 2 x 28mm 2 x 35mm 4 x 40mm clips Zinc plated for corrosion resistance Voltage 230V 50Hz Outlet Thre...

Page 12: ......

Reviews: