Clarke 7230096 Operation & Maintenance Instructions Manual Download Page 5

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard

.

If the colours of the wires in the power cable do not agree with the markings 
on the plug.

• The BLUE wire must be 

connected to the 
terminal marked N or 
coloured black.

• The BROWN wire must 

be connected to the 
terminal marked L or 
coloured red.

• The YELLOW AND 

GREEN wire must be 
connected to the 
terminal  marked E or 

 or coloured green.

AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING 
CURRENT OF LESS THAN 30MA MUST BE USED.

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs. 

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE 
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Summary of Contents for 7230096

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC1221 ISS 5 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE PUMP MODEL NO SWP900A PART NO 7230096...

Page 2: ...red with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guar...

Page 3: ...and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 DO NOT pump explosive...

Page 4: ...national com or Service clarkeinternational com OVERVIEW Remove all packaging and make sure that the unit contains no visible damage Dispose of all packaging appropriatly 1 FLOAT SWITCH 4 HANDLE 2 WAT...

Page 5: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the ter...

Page 6: ...ins plug to a high sensitivity residual current device RCD which has a tripping current of less then 30mA 4 Switch the mains power supply on The pump will begin to drain water As the water level falls...

Page 7: ...bris from around the impeller NOTE Do not attempt to repair the pump yourself as you may damage the waterproof seal and invalidate your guarantee Repairs must be carried out by your CLARKE dealer or c...

Page 8: ...ur CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift...

Page 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 10: ...over 3 Footing 15 Screw 27 O Ring 4 Casing Cover 16 Mechanical Seal 28 Upper Motor Cover 5 O Ring 17 O Ring 29 Gland Cover 6 Screw 18 Rotor 30 O Ring 7 O Ring 19 Motor Frame 31 Screw 8 Casing 20 Beari...

Page 11: ...in 1 3 Diameter 26 piece assorted hose clip set in various sizes Including 8 x16mm 6 x 22mm 4 x 25mm 2 x 28mm 2 x 35mm 4 x 40mm clips Zinc plated for corrosion resistance Voltage 230V 50Hz Outlet Thre...

Page 12: ......