Safety Precautions

WARNING:

 As with all machinery, there are certain hazards involved with their operation and

use. Exercising respect and caution will considerably lessen the risk of personal

injury. However, if normal safety precautions are overlooked or ignored, personal

injury to the operator or damage to property, may result.

 

Care must be taken when handling water near electricity as there is risk of electric

Never

use the unit near heaters or other sources of heat.

Never

place anything on the top of this unit, and never
obstruct the air intake/exhaust grills.

Never

pour or spray water on the unit.

Never

use solvent cleaners or other flammable liquids
to clean the unit.

Never

pull out the plug to stop or start the machine. Use
the ON/OFF switch on the side of the unit.

Never

pull on the mains cable to pull the plug from the
socket or to move the machine

WARNING!  Read these safety instructions before using the equipment.

Always

transport, store and operate this equipment in an
upright position

 DO NOT

 lay the unit down.

Always

leave the unit to stand for 15 minutes minimum before
switching on if it has been tilted or moved from an
upright position i.e. after transportation or cleaning.

Always

allow a gap of 300mm around the unit to allow
air to circulate.

Always

ensure that  the air inlet and outlet areas are
clear.

Always

remove the mains plug from the mains supply before
carrying out  any maintenance.

Always

switch off, unplug and drain any water from the
dehumidifier before moving.

Always

switch the electrical supply off and disconnect from
the mains, when not in use.

-3-

Summary of Contents for 6470636

Page 1: ...0807 MODEL NO DMD66 PART No 6470636 DEHUMIDIFIER DEHUMIDIFIER OPERATION MAINTENANCE INSTRUCTIONS ...

Page 2: ... 230v 7 3A 110v Refrigerant R417A R59 Temperature Range 5º to 35ºC Weight 44Kg Dimensions 770mm H x 565mm W x 460mm D Max Motor Wattage When Running 820W Max Extraction Rate 60 litres 24 hrs CLARKE GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a pe riod of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the...

Page 3: ... the plug to stop or start the machine Use the ON OFF switch on the side of the unit Never pull on the mains cable to pull the plug from the socket or to move the machine WARNING Read these safety instructions before using the equipment Always transport store and operate this equipment in an upright position DO NOT lay the unit down Always leave the unit to stand for 15 minutes minimum before swit...

Page 4: ...ed as follows Connect GREEN YELLOW coloured cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN YELLOW Connect BROWN cord to terminal marked with a letter L or coloured RED Connect BLUE cord to terminal marked with a letter N or coloured BLACK Fuse Rating The fuse in the plug must be replaced with one of the same rating 13amp and this re placement must be ASTA a...

Page 5: ...egin dehumidifying drying The water collected can be drained automatically using the hose connected to the drip tray drain Ensure the hose is kept below the level of the drain otherwise flooding of the unit will occur Drain condensate into a suitable container builders bucket or similar It is important to keep an eye on the water level in the bucket and empty regularly to prevent it from overflowi...

Page 6: ...tion where it is safe to use compressed air to blow the unit out ensuring you wear the necessary safety equipment especially safety glasses and ear defenders Covers removed THERMAL OVERLOAD The DMD66 transformer is protected with an internal 10 amp resettable circuit breaker see Illustration opposite The breaker is accessed by removing the bottom panel 5 screws at the rear of the dehumidifier In t...

Page 7: ... low switch unit OFF and add heat to area If temp is too high switch the unit Off and wait for temperature to drop Air intake exhaust grills obstructed Temperature outside of specified operating range Coils Dirty Water leaking Blocked drain hose Water receptacle full and overflowing Drain hose higher than the outlet port Unit has been moved without draining the inner drip tray Unit iced up Clear b...

Page 8: ...BW020371 Drip Tray 1 15 EL030602 Transformer 1 16 FR020302 Filter Drier 1 17 ME040129 Right Angle Coupling 1 18 ME040131 Condensate Tube 1 19 EL030511 Hour Clock 1 20 ME040207 Cable Gland 1 21 FI060405 Star Washer 2 22 ME010102 Wheels 2 23 EL030510 Timer 1 24 BW020352 Lower Case 1 25 FR030309 CD DX Coil 1 26 EL010210 Circuit Breaker 1 27 EL030906 Resistor 1 28 EL030123 Voltage Selector Switch 1 29...

Page 9: ...Parts Diagram 8 ...